10
(5)
Configure DO report when sensor restore
(When the vibration stops, R313FA1 will report an uplink package)
Downlink: 07C7010000000000000000
Response
:
87C7000000000000000000 (configuration success)
87C7010000000000000000 (configuration failure)
(6)
Read device parameters
Downlink: 08C7000000000000000000
Response
:
88C7010000000000000000 (device current parameter)
5.5 Example of MinTime/MaxTime logic
Example#1
based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
Max Time Max Time
S
leeping (Min Time)
S
leeping (Min Time
)
1H 2H 3H
Note:
MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange
value.
Example#2
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
Sleeping (MinTime) sleeping sleeping sleeping
0H
15
th
M 30
th
M 45
th
M
1H
2H
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORTS 2.8V
Wakes up and
collects data
REPORT 2.8V
Wake up and
collects data
REPORTS 2.8V
Wakes up and
collects data
REPORTS 2.8V
Wakes up and
collects data
REPORTS 2.8V
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
2.8V
Does not report