6
(1)
Command Configuration:
MinTime = 1min
、
MaxTime = 1min
、
BatteryChange = 0.1v
Downlink
:
0102003C003C0100000000 003C(H
ex)
= 60(D
ec)
Response
:
8102000000000000000000
(
Configuration success
)
8102010000000000000000
(
Configuration failure
)
(2)
Read Configuration:
Downlink
:
0202000000000000000000
Response
:
8202003C003C0100000000
(
Current configuration
)
Example for MinTime/MaxTime logic:
Example#1
based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
Max Time Max Time
S
leeping (Min Time)
S
leeping (Min Time
)
1H 2H 3H
Note:
MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange
value.
Description
Device
CmdID
Device
Type
NetvoxPayLoadData
Config
ReportReq
R313A
0x01
0x02
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
Battery
Change
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed 0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,
Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:
s)
MaxTime
(2bytes Unit:
s)
Battery
Change
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed 0x00)
Wake up and
collects data
REPORTS 2.8V
Wakes up and
collects data
REPORTS 2.8V
Wakes up and
collects data
REPORTS 2.8V