4.Set up Instruction 

On/Off 

 

Power on 

Insert batteries. (users may need a screwdriver to open); 

Insert two sections of 3V CR2450 button batteries and close the battery cover.) 

Turn on   

Press any function key till green and red indicator flashes once.   

Turn off (Restore to factory setting) 

Press and hold both function keys for 5 seconds till green indicator flashes for 20 times. 

Power off 

Remove Batteries.   

Note: 

1.

 

Remove and insert the battery; the device memorizes previous on/off state by default. 

2.

 

On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor 

inductance and other energy storage components. 

3.

 

Press any function key and insert batteries at the same time; it will enter engineer testing 

mode.   

Network Joining 

 

Never joined the network 

Turn on the device to search the network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

Turn on the device to search the previous network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Fail to join the network   

(when the device is on) 

Suggest to check the device verification information on the gateway with your platform 

server provider. 

Function Key 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes for 20 times: success 

The green indicator remains off: fail 

Press once   

The device is in the network: green indicator flashes once and sends a report 

The device is not in the network: green indicator remains off 

Sleeping Mode 

 

The device is on and in the 

network 

Sleeping period: Min Interval. 

When the reportchange exceeds setting value or the state changes: send a data report 

according to Min Interval.   

Low Voltage Warning 

Low Voltage 

2.4V 

Содержание R311W

Страница 1: ...ogy Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10 ...

Страница 3: ...mpared with other communication methods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring It has features like small size low power consumption long ...

Страница 4: ...tible with LoRaWANTM Class A Frequency hopping spread spectrum technology Configuration parameters can be configured through third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Indicator Water Leak Sensor Function Key ...

Страница 5: ... on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join the network when the device is on Suggest to check the device verification information on the gateway...

Страница 6: ...he device will immediately send a version packet report along with an uplink packet including battery voltage leak status The device sends data in the default configuration before any configuration is done Default setting Maximum time 3600s Minimum time 3600s Battery 0x01 0 1V R311W sensor is triggered When the R311W status changes it will send warning report No water leak 0 Water leak 1 Note The ...

Страница 7: ...0000000000 Configuration failed 2 Read R311W device parameters Downlink 0206000000000000000000 Device returns 8206003C003C0100000000 Current configuration Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq R311W 0x01 0x06 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1v Reserved 4Bytes Fixed 0x00 Config ReportRsp 0x81 Status 0x00_success Reserved 8Byt...

Страница 8: ...1H 25th M 1H 40th M 1H 55th M 2H 10th M Notes Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORT 2 8V Wakes up and collects data REPORTS 2 8V Wakes up and collects data 2 7V 2 7 2 8 0 1 REPORTS 2 7V Wakes up and collects data 2 7V Does not report Wakes up and collects data 2 7V Does not report Wakes up and collects data 2 7V Do...

Страница 9: ...s according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pus...

Страница 10: ...ach it to a flat ground position where it may accumulate water leaks As shown in the enlarged view on the right The figure shows that the water immersion sensor R311W is used in bathing rooms where there is a possibility of water leakage in the pipeline It can also be applied to the following scenarios Data center and computer room Document storage center Basement leak monitoring Water pipe leak d...

Страница 11: ...ion High temperature can shorten the life of electronic devices destroy batteries and deform or melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicat...

Отзывы: