5.2 GlobalCalibrateCmd
Fport : 0x0E
(1)
Setting GlobalCalibrate Configuration:
Assuming that the current measured distance of R311LA is 3001, it should be corrected to 3000, and
the difference is 3000-3001=-1;
Channel 1= 00,Multiplier = 0001,Divisor = 0000,DeltValue= -1 (0xFFFF)
Downlink
:
01360000010000FFFF0000
Response
:
8136000000000000000000
(
Configuration success
)
8136010000000000000000
(
Configuration failure
)
(2)
Getting GlobalCalibrate Configuration:
Downlink
:
0236000000000000000000
Response
:
8236000000000000000000
(
Configuration success
)
82360000010000FFFF0000
(
Configuration failure
)
Description
Cmd
ID
Sensor
Type
PayLoad(Fix =9 Bytes)
SetGlobal
CalibrateReq
0x01
0x36
Channel
(1Byte)
0_Channel 1,
1_Channel 2,etc
Multiplier
(2bytes,Unsigned)
Divisor
(2bytes,Unsigned)
DeltValue
(2bytes,Signed)
Reserved
(2Bytes,Fixed
0x00)
SetGlobal
CalibrateRsp
0x81
Channel
(1Byte)
0_Channel1,
1_Channel2,etc
Status
(1Byte,0x00_success)
Reserved (7Bytes,Fixed 0x00)
GetGlobal
CalibrateReq
0x02
Channel
(1Byte)
0_Channel1,
1_Channel2,etc
Reserved
(8Bytes,Fixed 0x00)
GetGlobal
CalibrateRsp
0x82
Channel
(1Byte)
0_Channel1,
1_Channel2,etc
Multiplier
(2bytes,Unsigned)
Divisor
(2bytes,Unsigned)
DeltValue
(2bytes,Signed)
Reserved
(2Bytes,Fixed
0x00)