4
Sleeping Mode
The device is on and in the
network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report according to Min Interval.
The device is on but not in
the network
First two mins: wake up every 15 seconds to send request.
After two mins: enter sleeping mode and wake up every 15 minutes to send request.
Note: Suggest to remove batteries if the device is not used.
Suggest to check device verification on gateway.
Low Voltage Warning
Low Voltage
2.4 V
5. Data Report
When the device is turned on, it will immediately send a version package.
Data will be reported once per hour by default setting.
Maximum time: Max Interval
Minimum time: Min Interval (Detect the current voltage value every Min Interval by default setting)
Default reportchange:
batteryvoltagechange ---- 0x01 (0.1V)
Remarks:
1. The device periodically sends data according to the maximum time. The data content is:
R311FB current device status.
2.
R311FB device will only report according to the minimum time when the battery voltage changes.
3.
The actual data sending cycle depends on real program before shipment.
R311FB vibration alarm:
The device detects sudden movement or vibration, and the quiescent state changes. The device waits for a certain period of time (DeactiveTime) to
enter the quiescent state and counts 1 time for the cumulative number, sends a report of the cumulative number of vibrations, and restarts the
preparation for the next detection. If the vibration continues to occur, the timing of DeactiveTime restarts until it reaches a standstill to count 1 time for
the cumulative number. The count data is not saved when it is powered off.
Can be changed by the gateway to change the device type, active vibration threshold and DeactiveTime.
The Active vibration threshold range is 0x0003-0x00FF (default is 0x0003);
DeactiveTime is 0x01-0xFF (default is 0x05);
R311F
DeviceType(1Bytes,0x01_
R311FA
,0x02_
R311FB
,0x03_
R311FC
), the default value is the programming value.
For the analysis of the data reported by the device, refer to the Netvox LoraWAN Application Command document and the
http://www.netvox.com.cn:8888/page/index
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable
Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number
between 1~65535
Any number
between 1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval