Example of ConfigureCmd 

FPort

0x07 

Bytes 

Var (Fix =9 Bytes) 

 

CmdID 

DeviceType 

NetvoxPayLoadData 

CmdID

– 1 byte 

DeviceType

– 1 byte – Device Type of Device 

NetvoxPayLoadData

– var bytes (Max=9bytes) 

 

Description 

Device 

Cmd

ID 

Device

Type 

NetvoxPayLoadData 

ConfigReport

Req 

R311 

DB 

0x01 

0xA9 

MinTime 

(2bytes Unit: s) 

MaxTime 

(2bytes Unit: s) 

BatteryChange 

(1byte Unit: 0.1v) 

Reserved 

(4Bytes, Fixed 0x00) 

ConfigReport

Rsp 

0x81 

Status 

(0x00_success) 

Reserved 

(8Bytes, Fixed 0x00) 

ReadConfig 

ReportReq 

0x02 

Reserved 

(9Bytes, Fixed 0x00) 

ReadConfig 

ReportRsp 

0x82 

MinTime 

(2bytes Unit: s) 

MaxTime 

(2bytes Unit: s) 

BatteryChange 

(1byte Unit: 0.1v) 

Reserved 

(4Bytes, Fixed 0x00) 

 

(1) Command Configuration: 

MinTime = 1min

  MaxTime = 1min

  BatteryChange = 0.1v 

Downlink

  01A9003C003C0100000000      // 003C(Hex) = 60(Dec) 

Response

 

81A9000000000000000000 (Configuration success) 

81A9010000000000000000 (Configuration failure) 

(2) Read Configuration: 

Downlink

  02A9000000000000000000 

Response

  82A9003C003C0100000000 (Current configuration

 

 

 

 

 

 

 

 

Содержание R311DB

Страница 1: ...ology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Important Maintenance Instruction 9...

Страница 3: ...spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic me...

Страница 4: ...igured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Low power...

Страница 5: ...sted to be about 10 seconds to avoid the interference of capacitor inductance and other energy storage components Network Joining Never joined the network Turn on the device to search the network to j...

Страница 6: ...d on it will immediately send a version package and an attribute report data The device sends data according to the default configuration before any other configuring Default setting Maximum time 3600...

Страница 7: ...0x00 ConfigReport Rsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s Bat...

Страница 8: ...M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORT 2 8V Wakes up and collects data REPO...

Страница 9: ...erval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation...

Страница 10: ...stic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device...

Отзывы: