background image

 

 

4.

 

Set up Instruction 

On/Off 

 

Power on 

Insert batteries. (users may need a flat blade screwdriver to open);   

Insert two sections of 3V CR2450 button batteries and close the battery 

cover.) 

Turn on   

Press any function key till green and red indicator flashes once.   

Turn off   

(Restore to factory setting) 

Press and hold the function key for 5 seconds till green indicator flashes for 20 

times. 

Power off 

Remove Batteries.   

Note: 

1.

 

Remove and insert the battery; the device memorizes previous on/off   

state by default. 

2. On/off interval is suggested to be about 10 seconds to avoid the interference 

of capacitor inductance and other energy storage components. 

3. Press any function key and insert batteries at the same time; it will enter 

engineer testing mode.   

Network Joining 

 

Never joined the network 

Turn on the device to search the network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

Turn on the device to search the previous network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Function Key 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes for 20 times: success 

The green indicator remains off: fail 

Press once   

The device is in the network: green indicator flashes once and sends a report 

The device is not in the network: green indicator remains off 

Содержание R311CC

Страница 1: ...ogy Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10 ...

Страница 3: ... greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring It has features like small size low power consumption long transmission distance strong anti interference ability and so on LoRaWAN LoRaWAN ...

Страница 4: ...h LoRaWANTM Class A Frequency hopping spread spectrum Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Indicator Function Key ...

Страница 5: ... inductance and other energy storage components 3 Press any function key and insert batteries at the same time it will enter engineer testing mode Network Joining Never joined the network Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The green ...

Страница 6: ...eported data is decoded by the Netvox LoRaWAN Application Command document and http loraresolver netvoxcloud com 8888 page index Sleeping Mode The device is on and in the network Sleeping period Min Interval When the reportchange exceeds setting value or the state changes send a data report according to Min Interval Low Voltage Warning Low Voltage 2 4V 5 Data Report Data report configuration and s...

Страница 7: ... 0x00 Config ReportRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s Battery Change 1byte Unit 0 1v Reserved 4Bytes Fixed 0x00 1 Command Configuration MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 016C003C003C0100000000 003C Hex 60 Dec Response 816C00000000000000...

Страница 8: ... based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Sleeping MinTime sleeping sleeping sleeping 0H 15th M 30th M 45th M 1H 2H Wakes up and collects data 2 8V Does not report Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORT 2 8V Wake up and collects data REPORTS 2 8V Wakes up and collects data REPORTS 2 8V Wakes up and...

Страница 9: ...e reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculation is started Wakes up and collects data...

Страница 10: ... it indoors 2 Dust in the installation position of the equipment needs to be wiped clean and then affixed to the equipment 3 The battery installation method is shown in the figure below battery with facing outward Note To install the battery use a screwdriver or similar tool to assist in opening the battery cover ...

Страница 11: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do no...