7
(1)
Configure R311CA device parameter MinTime = 1min
、
MaxTime = 1min
、
BatteryChange = 0.1v
Downlink
:
014C003C003C0100000000
Device return
:
814C000000000000000000 (configuration success)
814C010000000000000000 (configuration failure)
(2)
Read R311CA device parameter
Downlink
:
024C000000000000000000
Device return
:
824C003C003C0100000000 (device current parameter)
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime MaxTime
Sleeping(MinTime) Sleeping(MinTime)
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BtteryVoltageChange
value.
Description
Device
CmdID
Device
Type
NetvoxPayLoadData
ConfigReport
Req
R311CA
0x01
0x4C
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed
0x00)
ConfigReport
Rsp
0x81
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfigR
eportReq
0x02
Reserved
(9Bytes, Fixed 0x00)
ReadConfigR
eportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed
0x00)
Wake up and collects data
REPORTS 2.8V
Wakes up and collects data
REPORTS 2.8V
Wakes up and collects data
REPORTS 2.8V