The following Information is for the advance user or 

developers only 

Содержание Contact Sensor Series

Страница 1: ...User Manual Wireless Window Door Sensor And Wireless Glass Sensor Model Z311C Contact Sensor Series FW V1 1 HW V0 1 V1 0 20130604...

Страница 2: ...Extended Magnet Extended Contact Internal Contact Red Green Indicator Binding Key Auxiliary Key Glass break sensor input Figure 1 Z311C device Extended Contact Input Battery Cover Glass break sensor...

Страница 3: ...il the door is closed and the CIE will receive an update notification and replace the currently open status with currently close status What is ZigBee ZigBee is a short range wireless transmission tec...

Страница 4: ...Step 3 The green indicator will flash 5 times upon join successful Otherwise the indicator will not flash The device will enter to sleep mode after 15 seconds of attempt to join To wake up the device...

Страница 5: ...arning Possible battery drainage When the device was once joined to a network and by any chance the network is no longer present or it is out of network it will wake up every 15 minutes to find the ne...

Страница 6: ...device in the security system Soon after the network join the next step is to enroll itself into a CIE Control and Indicating Equipment security system device to validate zone alarm feature The regis...

Страница 7: ...us change within 2 seconds to avoid potential traffic jam of communication Glass break detection application The glass breaking vibration wave would cause the sensor attached on the glass to vibrate w...

Страница 8: ...d on its LED indicator when reassignment configuration is completed 2 In the case that you are assigning Z311C to a different CIE security system other than the one registered after new registration s...

Страница 9: ...ed the heartbeat of a device implemented within the firmware of Z311C and other Netvox security zone devices When Z311C had just registered itself to the security CIE system it sends the very first he...

Страница 10: ...voltage for Z311C is between 2 1 3 6V DC It performs the first battery level check when the battery is loaded The device performs battery level check in a period of time Anything bellow 2 1V a batter...

Страница 11: ...The following Information is for the advance user or developers only...

Страница 12: ...f the device or a detected glass break Z311C sends out Zone status attribute as Alarm1 having the attribute value of 1 for alarmed When the magnetic contact piece is close or attached to it Z311C send...

Страница 13: ...sion Unsigned 8 bit integer 0x00 0xff Read only 0x0C O 0x0004 ManufacturerName Character string 0 32 bytes Read only netvox O 0x0005 ModelIdentifier Character string 0 32 bytes Read only Z311CE0ED O 0...

Страница 14: ...ce please keep the supplied jumper head attached on the pin connection otherwise Z311C will not function properly 9 Make sure that the glass and magnetic contact sensor should not be swapped The corre...

Страница 15: ...a more stable zone device Detection Range Radius of 180 cm Detection Method Piezoelectric Alarm Period 0 5sec 6 sec Alarm Output Semiconductor style switch polarity DC24V 40mA Resistance at 13 ohm max...

Страница 16: ...wirelessly things becomes much easier Our ZiG BUTLER allows you to do that Of course any other 3rd party ZigBee enabled software is also applicable ZiG BUTLER software is to be installed on a PC or a...

Страница 17: ...nu select Set PermitJoin On When Z311C has successfully joined you should see the Z311C device icon appeared in ZiG BUTLER View Zone Status Move your mouse to the circle on top of Z311C icon Figure B...

Страница 18: ...e red circle area is the information of status Alarm1 shows ON meaning door open is been detected The door status is currently open Configuring Heartbeat of Z311C Move your mouse to the featured icon...

Страница 19: ...In the drop down menu select Properties A configuration box should appear similar to the one bellow Click on Advance tab Figure 4 Advance tab IAS Zone...

Страница 20: ...ise it will be blank Click on the dropdown arrow next to the IAS CIE ADDRESS and select a preferred CIE system device Now make sure you have wake up Z311C device which normally go to sleep when idle O...

Страница 21: ...a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and c...

Страница 22: ...e with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause...