background image

                                     

NV-600LI/RI Managed Industrial Grade VDSL2 CO/CPE Router USER’S MANUAL Ver. A4   

                                                               

                                                                                                         

115 

If the VDSL2 Router has been powered up already you will see a prompt by hitting the ENTER key. 

A screen is displayed as shown in 

Figure 6.2

 

 

Figure 6.2 Command Line

 

Note: 

As you may identify from the commands above Industrial VDSL2 Router is a Linux based device. 

Many of the common Linux commands can be used here. However, please consider that you purchased a VDSL2 router device, not a PC. 

And always keep in mind that provider gives you support for configuring a standard VDSL2 router. If you try to use the VDSL2 router as a 

Linux hardware platform and modify its internal software structure, there is no support or warranty on the unit. 

Содержание NV-600LI

Страница 1: ...Ma a an n na a ag g ge e ed d d I I In n nd d du u us s st t tr r ri i ia a al l l G G Gr r ra a ad d de e e V V VD D DS S SL L L2 2 2 C C CO O O C C CP P PE E E R R Ro o ou u ut t te e er r r U U US...

Страница 2: ...roperty rights of any third party Statement of Conditions In the interest of improving internal design operational function and or reliability NETSYS reserves the right to make changes to the products...

Страница 3: ...ormance broadband multimedia services to industrial environments such as Factories MRT Train stations Ticket vending machines Parking systems Monitoring systems and point to point applications The NV...

Страница 4: ...cate the product where anyone can work on the power cord DO NOT install nor use your device during a thunderstorm There may be a remote risk of electric shock from lightning DO NOT expose your device...

Страница 5: ...VDSL2 ROUTER SOLUTION 2 SAFETY WARNINGS 3 CHAPTER 1 UNPACKING INFORMATION 9 1 1 Check List 9 CHAPTER 2 INSTALLING THE ROUTER 9 2 1 Hardware Installation 10 2 2 Pre installation Requirements 10 2 3 Gen...

Страница 6: ...3 1 Front Panel 20 3 2 Front Indicators 21 3 3 Rear Panel 22 3 4 Side Panel 23 CHAPTER 4 CONFIGURE THE NV 600LI RI VIA WEB BROWSER 28 4 1 Login 29 4 2 Select the Menu Level 30 4 3 Select SYSTEM 32 4 3...

Страница 7: ...S 47 4 5 Select LAN 48 4 5 1 Select LAN Settings and set the IP Address 49 4 5 2 DHCP Client List 51 4 5 3 LAN Switch Port Setting 52 4 5 4 LAN Port Status 53 4 6 Select NAT 54 4 6 1 Virtual Server 55...

Страница 8: ...74 4 10 1 SNMP Setting 75 4 10 2 SNMPv3 Setting 77 CHAPTER 5 OPERATING THE VDSL2 SYSTEM 80 5 1 Select Channel Config 82 5 2 Select Line Config 86 5 3 Select Profile Config 88 5 4 Select Loop Back 98 5...

Страница 9: ...NSOLE 114 6 1 Setup on Hyperterminal 114 6 2 Check IP via CLI command 116 6 3 Reset the system to default configuration 117 APPENDIX A CABLE REQUIREMENTS 118 APPENDIX B PRODUCT SPECIFICATION 120 APPEN...

Страница 10: ...x 6pin Terminal Block 1 x 2pin Terminal Block Notes 1 Please inform your dealer immediately for any missing or damaged parts If possible retain the carton including the original packing materials Use...

Страница 11: ...uding power requirements sufficient physical space and proximity to other network devices that are to be connected Verify the following installation requirements Power requirements DC 12 to 48VDC redu...

Страница 12: ...HUB and an end node VDSL2 Port RJ 11 All network connections to the RJ 11port must use 24 26 gauge with twisted pair phone wiring We do not recommend the use of the telephone line 28 gauge or above Th...

Страница 13: ...t half duplex Use any of the Ethernet ports to connect to devices such as Monitor system Server Switch bridge or router Note 1 The RJ11 Line port is used to connect to telephone that is connected to V...

Страница 14: ...ng Take out the 2pin 6pin terminal block from inside the accessory kit and install to the router properly Figure 2 6 1 Please refer to install the DIN RAIL as following step 1 Install the DIN Rail mou...

Страница 15: ...e Either RJ 11 port is connected or terminal block is connected using straight connection Figure 2 4 or cross over connection Figure 2 5 Figure 2 4 NV 600LI RI line ports straight connection Figure 2...

Страница 16: ...exceed 100 meters 333 feet 2 We advise using Category 5 7 UTP STP cables for making Bridge or Router connections to avoid any confusion or inconvenience in the future when you attach high bandwidth de...

Страница 17: ...3km for data service across existing phone wiring It is easy to use which do not require installation of additional wiring Every modular phone jack in the home can become a port on the LAN Networking...

Страница 18: ...NV 600LI RI Managed Industrial Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 17 Figure 2 7 NV 600LI RI industrial grade application...

Страница 19: ...dware representation of a cable network with or without noise injection and crosstalk simulations 2 7 2 Connect the NV 600LI and the NV 600RI to LAN Devices In the setup usually an Ethernet tester ser...

Страница 20: ...al Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 19 Chapter 3 Hardware Description This section describes the important parts of the router It features the front panel side panel and rear panel NV 60...

Страница 21: ...t is easy to determine if it has Ethernet signal from its RJ 45 port and if there is vdsl line signal on RJ 11 port And the table shows the description Table 3 1 Table 3 1 Description of the router fr...

Страница 22: ...device has a good Ethernet connection Blinking The device is sending or receiving data ETHERNET 1 4 Ethernet LED Green Off The LAN is not connected On Steady The Internet or network connection is up...

Страница 23: ...VDSL2 CO CPE Router USER S MANUAL Ver A4 22 3 3 Rear Panel The rear panel provides the din rail install hole The following figure shows the rear panel Figure 3 3 Figure 3 3 Rear Panel Note Please refe...

Страница 24: ...rs The following description introduce Dual power and Relay Contact Wiring the dual Power Inputs The NV 600LI RI has two sets of power inputs power 1 and power 2 which are located on the NV 600I s sid...

Страница 25: ...ing NV 600LI RI will enable Reverse Polarity Protection function automatically DC power will not be able to directly through the machine 2 Please note that if the DC power current exceeds 3A NV 600LI...

Страница 26: ...OFF 24V ON No Power OFF 48V ON 48V ON Example 4 Example 5 Example 6 Power Item Default Polarity Power Input1 Output State1 Power Input2 Output State2 Power Input1 Output State1 Power Input2 Output St...

Страница 27: ...onnect the relay contact Fault Tip The relay contacts of the 6 pin terminal block connector are used to detect user configured events The three wires attached to the fault contacts form an open circui...

Страница 28: ...route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point Note Do not run signal or communications wiring a...

Страница 29: ...using Chrome or Firefox browsers In order to use the web browser configure the device you may need to allow Web browser pop up windows from your device Web pop up blocking is enabled by default in win...

Страница 30: ...NV 600LI RI Managed Industrial Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 29 4 1 Login The default password is admin The password is changeable in Administrator Settings Figure 4 1 Login Password...

Страница 31: ...outer USER S MANUAL Ver A4 30 4 2 Select the Menu Level There is an easy Setup for end users at the setup of NV 600LI RI with SYSTEM WAN LAN NAT FIREWALL ROUTE UPNP VDSL2 SNMP for more detail configur...

Страница 32: ...NV 600LI RI Managed Industrial Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 31 Figure 4 2 2 Select the Menu Level NV 600RI...

Страница 33: ...4 3 Select SYSTEM Select the SYSTEM The menu below will be used frequently It includes the sub menus of Administrator Setting System Time Firmware Upgrade Device Mode System Status Reboot Reset System...

Страница 34: ...etting To add a user or change user s password click on the Administrator Settings link in the left navigation bar A screen is displayed as shown in Figure 4 3 1 Figure 4 3 1 Administrator Settings Co...

Страница 35: ...The synchronized clock in the Modem is used to record the security log and control client filtering A screen is displayed as shown in Figure 4 3 2 Figure 4 3 2 System Time Configuration Note Static Ro...

Страница 36: ...Firmware Upgrade link in the left navigation bar A screen is displayed as shown in Figure 4 3 3 Figure 4 3 3 Firmware Upgrade The screen contains the following detail Click Browse to select a specific...

Страница 37: ...e firmware upgrade must be reset system to default to avoid the new features can not use or system error 2 2 4 20_mvl31 ADM5120 of kernel version means the CPU number of an IC 1647 means a serial numb...

Страница 38: ...click on the Device Mode link in the left navigation bar A screen is displayed as shown in Figure 4 3 4 Figure 4 3 4 Device Mode Notes 1 The default setting is in Switch Bridge mode it is not necessar...

Страница 39: ...al Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 38 4 3 5 System Status To view system status click on the System Status link in the left navigation bar A screen is displayed as shown in Figure 4 3 5...

Страница 40: ...USER S MANUAL Ver A4 39 4 3 6 Reboot To reboot the unit click on the Reboot link in the left navigation bar A screen is displayed as shown in Figure 4 3 6 Figure 4 3 6 Reboot Click Reboot to restart t...

Страница 41: ...layed as shown in Figure 4 3 6 Figure 4 3 7 Reset NV 600LI RI Router Click Reset button to restart the system to default configuration After upgrade the firmware and then automatically reboot All sett...

Страница 42: ...R S MANUAL Ver A4 41 4 4 Select WAN Select the WAN The menu below includes the sub menus of Dymanic IP IP Settings PPPoE and DNS A screen is displayed as shown in Figure 4 4 Figure 4 4 WAN type in the...

Страница 43: ...terface to dynamically obtain an IP Address click on the Dynamic IP link in the left navigation bar A screen is displayed as shown in Figure 4 4 1 Figure 4 4 1 Dynamic IP Configuration The screen cont...

Страница 44: ...Ver A4 43 4 4 2 IP Settings To configure the WAN interface to use a Static IP Address click on the Static IP link in the left navigation bar A screen is displayed as shown in Figure 4 4 2 Figure 4 4...

Страница 45: ...ddress of the NV 600LI RI Does ISP provide more IP Address Provides more IP Addresses of the WAN interface Select the check box to enable this option A screen is displayed as shown in Figure 4 4 2 Cli...

Страница 46: ...r USER S MANUAL Ver A4 45 4 4 3 PPPoE To configure the WAN interface to use PPPoE click on the PPPoE link in the left navigation bar A screen is displayed as shown in Figure 4 4 3 Figure 4 4 3 PPPoE C...

Страница 47: ...smitted between LAN port and WAN port or between NV 600LI RI and WAN the connection is disconnected after the Maximum idle time If the Auto reconnect check box is selected the PPP connection is re est...

Страница 48: ...gure 4 4 4 Figure 4 4 4 DNS Configuration The screen contains the following details Fields in DNS Field Description Domain Name Server DNS Address Enter the DNS address of the primary DNS server Secon...

Страница 49: ...nsole then the menu below will be helpful In order to set the IP address click on LAN Settings Select the LAN The menu below includes the sub menus of LAN Settings DHCP Client List LAN Switch Port Set...

Страница 50: ...he default address of adm0 or it is the address changed by an ifconfig command via the shell running in the terminal The Subnet Mask display can be ignored In case the DHCP checkbox is checked some ad...

Страница 51: ...en contains the following details Fields in LAN Settings Field Description IP Address Enter the LAN interface IP Address of NV 600LI RI Web IP Subnet Mask Enter the LAN Subnet Mask of NV 600LI RI The...

Страница 52: ...to see which clients are connected to the VDSL2 CPE Modem via IP address host name and MAC address To view the DHCP client list click on the DHCP Client List link in the left navigation bar A screen...

Страница 53: ...ing click on the Lan Switch Port Setting link in the left navigation bar A screen is displayed to all LAN Port Setting as shown in Figure 4 5 3 Figure 4 5 3 LAN Switch Port Setting Default value is Au...

Страница 54: ...ent Ethernet ports status of the unit A screen is displayed to Status as shown in Figure 4 5 4 Figure 4 5 4 LAN Port Status Example Table Input 1 Output 1 Input 2 Output 2 Input 3 Output 3 Input 4 Out...

Страница 55: ...the internet through a single public IP address or multiple public IP address NAT can also prevent hacker attacks by mapping local address to public address for key services such as the Web or FTP Sel...

Страница 56: ...ses can be automatically redirected to local servers configured with private IP addresses In other words depending on the requested service TCP UDP port numbers the Router redirects the external servi...

Страница 57: ...ecified entry Private Port Enter a private Port number of the specified entry Type Select virtual server protocol type of the specified entry Public Port Enter a public port number of the internet use...

Страница 58: ...sign a set or a range of ports to a specified local machine to route the packets Router allows the user to configure the needed port mappings to suit such applications To configure Port Mapping click...

Страница 59: ...apping Field Description Server IP Enter the IP Address of a specified local machine Mapping Port Assign a range of port or specific port number to route the packets Enabled Enable a specified entry o...

Страница 60: ...hat cannot run an Internet application properly from behind the NAT firewall you can open the client up to unrestricted two way Internet access by defining a virtual DMZ Host To configure the DMZ clic...

Страница 61: ...60 The screen contains the following details Fields in DMZ Field Description Enable Enable or disable the DMZ setting of NV 600LI RI Select the check box to enable this option IP Address Enter IP Addr...

Страница 62: ...the risk of instrusion and defending against a wide array of common hacker attacks However for applications the require unrestricted access to the internet you can configure a specific client server a...

Страница 63: ...om testing the services of the VDSL2 CO Modem Discard ping from WAN side cause the VDSL2 CO Modem not to respond to the hacker scan packets from the public WAN IP address To enable the firewall option...

Страница 64: ...to log and drop all the hacker attack events Discard PING from WAN Select the check box to drop all PING from the WAN side Discard PING the Gateway Select the check box to drop all PING to NV 600LI R...

Страница 65: ...SL2 CO CPE Router USER S MANUAL Ver A4 64 4 7 2 Client Filtering To enable Client Filter click on the Client Filtering link in the left navigation bar A screen is displayed as shown in Figure 4 7 2 Fi...

Страница 66: ...check box to enable this option IP Enter the filter IP Address range of the local machines under VDSL2 CO CPE ROUTER Port Enter the filter Port number range of the local machines under VDSL2 CO CPE RO...

Страница 67: ...r A4 66 4 7 3 MAC Control You can block certain client PCs accessing the Internet based on MAC addresses To configure MAC Control click on the MAC Control link in the left navigation bar A screen is d...

Страница 68: ...Address Control Enable or disable the MAC address control Block Connection to Internet Enable or disable block status If the check box is selected it blocks the specified MAC address MAC Address Assi...

Страница 69: ...re are multiple routers installed on your network it is necessary to configure the VDSL2 router unit s routing functions Select the Route The menu below includes the sub menus of Static Routing and Ro...

Страница 70: ...llows over your network before and after it passes through your router You can use static routing to allow different IP domain users to access the Internet through this VDSL2 Router device To setup St...

Страница 71: ...e Subnet Mask 0 0 0 0 of routing entry Gateway Enter the Gateway address of routing entry Click Add to add the information that has been entered Note 1 Static Routing functionality is used to define t...

Страница 72: ...your VDSL2 router routing table and interface information To view the Routing entry table list of NV 600LI RI click on the Routing Table List link in the left navigation bar A screen is displayed as...

Страница 73: ...factors It is designed to bring easy to use flexible standards based connectivity to ad hoc or unmanaged networks whether in the home in a small business public spaces or attached to the Internet The...

Страница 74: ...ds in UPnP Settings Field Description Enable UPnP To enable or disable UPnP Setting Select the check box to Enable or Disable the UPnP function of SPEED VDSL2 CO CPE ROUTER Click APPLY at any time dur...

Страница 75: ...e VDSL2 CO CPE Router USER S MANUAL Ver A4 74 4 10 Select SNMP The SNMP Settings can be viewed in the left navigation bar The following are the options available under SNMP as shown in Figure 4 10 Fig...

Страница 76: ...VDSL2 CO CPE Router USER S MANUAL Ver A4 75 4 10 1 SNMP Setting To enable or disable the SNMP Settings click on the SNMP Setting link in the left navigation bar A screen is displayed as shown in Figu...

Страница 77: ...uests accompanied by this string to display MIB object information Deafult word is public Read Write community Enables requests accompanied by this string to display MIB object information and to set...

Страница 78: ...CO CPE Router USER S MANUAL Ver A4 77 4 10 2 SNMPv3 Setting To enable or disable the SNMPv3 Settings click on the SNMPv3 Setup link in the left navigation bar A screen is displayed as shown in Figure...

Страница 79: ...tails Figure 4 10 2 1 SNMPv3 Setting Disable Fields in SNMPv3 Settings A screen is displayed as shown in Figure 4 10 2 1 Field Description Enable SNMPv3 To enable or disable SNMP Setting Select the ch...

Страница 80: ...ct information Read Write Enables requests accompanied by this string to display MIB object information and to set MIB objects User name Specifies the user name 1 15 chars Security Level Specifies sec...

Страница 81: ...L2 Configuration of operation modes test modes loop back and the display of status information are supported by GUI Graphical User Interface Select the Route The menu below includes the sub menus of C...

Страница 82: ...s 5 4 Loop Back Setting Of Loop Backs System System Loop or Line Side Loop 5 5 Activate Deactivate Activating or Deactivating the line 5 6 Line Status Downstream Upstream SNR status of the Line 5 7 Ch...

Страница 83: ...SL2 CO CPE Router USER S MANUAL Ver A4 82 5 1 Select Channel Config To config the VDSL2 channel click on the Channel Config link in the left navigation bar A screen is displayed as shown in Figure 5 1...

Страница 84: ...time during configuration to save the information that you have entered Click CANCEL to exit from this page without saving the changes Notes 1 Regarding the interleave delay value time function for a...

Страница 85: ...n the data cannot be correctly decoded Short bursts of noise on the line can cause these data packets to become corrupt and the router has to re request data which in turn can slow down the overall ra...

Страница 86: ...y because if you lose a whole batch of data then this could cause your router to loose sync with the exchange Using Interleaving the router is able to re assemble the data or if necessary just re requ...

Страница 87: ...CO CPE Router USER S MANUAL Ver A4 86 5 2 Select Line Config To config the Line click on the Line Config link in the left navigation bar A screen is displayed as shown in Figure 5 2 Figure 5 2 Line C...

Страница 88: ...routers often use the terms Noise Margin or SNR when reporting on its value The Signal to Noise Ratio as its name implies is the ratio between the strength of the signal and the level of noise on the...

Страница 89: ...ound primarily in APAC NV 600 has numerous configuration profiles and bandplans to meet regional service provider requirements The frequency bandwidth has increased to 30 MHz with configuration option...

Страница 90: ...Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 89 To config the Profile click on the Profile Config link in the left navigation bar A screen is displayed as shown in Figure 5 3 1 5 3 2 Figure 5 3 1 N...

Страница 91: ...0RI Profile Configuration Click APPLY at any time during configuration to save the information that you have entered Click CANCEL to exit from this page without saving the changes Note Filter and Tone...

Страница 92: ...NV 600LI RI Managed Industrial Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 91 Figure 5 3 3 Band Profile and Plan Setup Error Figure 7 1 3 4 Band Profile Region...

Страница 93: ...Profile8c 8 Annex B 997 M2x A B05 3 VDSL2 Profile8d 9 Annex B 997 M2x M B06 4 VDSL2 Profile12a 10 Annex B 997 M1c A 7 B07 5 VDSL2 Profile12b 11 Annex B 998 M1x B B08 6 VDSL2 Profile17a 13 Annex B 998...

Страница 94: ...O X X X X X X X X 2 X X O X O X X O X X X X X X X X X 3 O O O X O O O O O X X X X X X X X 4 O O O O O O O O O X X X X X X X X 5 O O X X O O O O O O X X X X X X X 6 O X X X O O O O O X O X X O X X O 7...

Страница 95: ...m 0 1 Mbps 19 Mbps 8a Annex B 997 M2x M B06 100 m 26 2 Mbps 56 6 Mbps 2200 m 0 5 Mbps 9 3 Mbps 8a Annex B 997 M1c A 7 B07 100 m 5 5 Mbps 75 8 Mbps 2000 m 0 1 Mbps 19 Mbps 8a Annex B 998 M1x B B08 100...

Страница 96: ...1 Mbps 5 8 Mbps 8d Annex A M1_EU32 100 m 6 5 Mbps 86 6 Mbps 2100 m 0 2 Mbps 16 2 Mbps 8d Annex A M9_EU64 100 m 7 5 Mbps 85 5 Mbps 2100 m 0 9 Mbps 8 3 Mbps 8d Annex B 997 M2x A B05 100 m 26 8 Mbps 58 4...

Страница 97: ...m 31 9 Mbps 88 4 Mbps 1500 m 1 1 Mbps 31 Mbps 12b Annex A M9_EU64 100 m 31 9 Mbps 87 9 Mbps 1500 m 1 3 Mbps 31 Mbps 12b Annex B 997 M1c A 7 B07 100 m 33 Mbps 82 5 Mbps 1400 m 0 9 Mbps 32 7 Mbps 12b An...

Страница 98: ...m 32 3 Mbps 100 Mbps 1300 m 1 Mbps 22 7 Mbps 17a Annex B 998E17 M2x NUS0 100 m 38 3 Mbps 100 Mbps 1300 m 1 3 Mbps 35 4 Mbps 17b Annex B 998 M2x M B11 100 m 29 4 Mbps 100 Mbps 2000 m 0 9 Mbps 8 1 Mbps...

Страница 99: ...lity back to the source without intentional processing or modification This is primarily a means of testing the transmission or transportation infrastructure The loop back testing function for checkin...

Страница 100: ...s Example applications Reference only Performing transmission tests of access lines from the serving switching center which usually does not require the assistance of personnel at the served terminal...

Страница 101: ...al Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 100 5 5 Select Activate Deactivate This function is for enable disable VDSL2 port A screen is displayed as shown in Figure 5 5 Figure 5 5 Activation a...

Страница 102: ...ctivate or deactivate the line Select the activity and the press the APPLY button Click APPLY at any time during configuration to save the information that you have entered Click CANCEL to exit from t...

Страница 103: ...SNR value for checking phone wiring quality A screen is displayed as shown in Figure 5 6 Figure 5 6 Line Status Display Actual SNR Note Band Actual SNR value if the value is 0 dB currently dose not tr...

Страница 104: ...e firmware showtime tc sync SHOWTIME TC SYNC corresponds to VDSL2 device state STEADY STATE TC SYNC Idle corresponds to the GEMINAX device state DISABLED and the VDSL2 device state RESET STATE SOCRATE...

Страница 105: ...raining TRAINING for VDSL2 this is a substate of FULL INIT and is not reported lowpower l3 LOWPOWER L3 not supported by VDSL2 analysis ANALYSIS for VDSL2 this is a substate of FULL INIT and is not rep...

Страница 106: ...hannel Status This function shows VDSL2 port status A screen is displayed as shown in Figure 5 7 Figure 5 7 Channel Status Note The channel status shows accurate value as data rate CRC INP etc when li...

Страница 107: ...MANUAL Ver A4 106 5 8 Select Version Info This function shows VDSL2 hardware and firmware version A screen is displayed as shown in Figure 5 8 Figure 5 8 Display of Version Data Note If you would lik...

Страница 108: ...s When NV 600LI link with NV 600RI this graph will show the SNR value for each band Shown power level in upstream and downstream spectrum The higher the SNR value the better the performance A screen i...

Страница 109: ...NV 600LI RI Managed Industrial Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 108 Figure 5 9 2 Display of NV 600RI SNR per Carrier...

Страница 110: ...er A4 109 Following graph shows the snr per tone expand graph please press Expand Graph button to get the graph A screen is displayed as shown in Figure 5 9 3 and Figure 5 9 4 Figure 5 9 3 NV 600LI sn...

Страница 111: ...Ver A4 110 Following chart shows the snr per tone expand value please press expand Show Raw Values button to get the chart A screen is displayed as shown in Figure 5 9 5 and Figure 5 9 6 Figure 5 9 5...

Страница 112: ...ANUAL Ver A4 111 5 10 Select Bits Graphs When NV 600LI link with NV 600RI this graph will show the bits value for each tone Shown tone length in upstream and downstream spectrum A screen is displayed...

Страница 113: ...ease press Expand Graph button to get the graph A screen is displayed as shown in Figure 5 10 2 Figure 5 10 2 snr per tone expand graph Following chart shows the bits per tone expand value please pres...

Страница 114: ...or nonexistent bits per tone in the high frequency band indicate the presence of a long loop If there is a major dip in the bits per tone graph but the noise power per tone graph does not show any abn...

Страница 115: ...CPE Router USER S MANUAL Ver A4 114 Chapter 6 Configure the NV 600LI RI via Console 6 1 Setup on Hyperterminal Open the Hyperterminal and set the baud rate to 115200 8N1N to properly set the hyperter...

Страница 116: ...may identify from the commands above Industrial VDSL2 Router is a Linux based device Many of the common Linux commands can be used here However please consider that you purchased a VDSL2 router devic...

Страница 117: ...V 600RI looks very similar A screen is displayed as shown in Figure 6 3 Figure 6 3 ifconfig Note You can use the serial Interface to configure an IP address by this command ifconfig adm0 ipadress netm...

Страница 118: ...t the system to default configuration At the CLI command write the command rawaccess e to reset the system to default configuration For it to take effect write the command reboot to restart the system...

Страница 119: ...sists of eight pins The Ethernet standard uses pins 1 2 3 and 6 for data transmission purposes Table A 1 Table A 1 RJ 45 Ethernet Connector Pin Assignments MDI MDI X PIN Signal Media Dependant interfa...

Страница 120: ...Managed Industrial Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 119 Figure A 2 Pin Assignments and Wiring for an RJ 45 Straight Through Cable Figure A 3 Pin Assignments and Wiring for an RJ 45 Cros...

Страница 121: ...SNMP v1 v2 v3 Supports SNR indicator for checking phone wiring quality Supports Interleave Delay to prevent against noise and data errors Support 8a 8b 8c 8d 12a 12b 17a 17b and 30a band profile Supp...

Страница 122: ...act terminal blocks for power1 and alarm contact 1 removable 2 contact terminal blocks for power2 Flow control Full duplex IEEE 802 3x Half duplex Back pressure LED Indicators 1 Power LED 4 Link Activ...

Страница 123: ...Ver A4 122 EMC EMI Compliant FCC Class A EMS Compliant CE mark Operating Temperature 20 C 70 C 4 F 158 F Fanless free air cooling Storage Temperature 40 C 70 C 40 F 158 F Humidity 5 to 95 non condensi...

Страница 124: ...measures fail to resolve the problem have the unit power supply replaced by a qualified distributor Note Please refer to power status table to check power input status Section 3 4 2 Symptom Link indic...

Страница 125: ...andard or above and without clustering otherwise will cause more cross talk issue to reduce DSL power driver 4 Problem What is VDSL2 Only reference Answer Very high speed digital subscriber line 2 VDS...

Страница 126: ...t s at 1 km 3 300 ft but degrades at a much slower rate from there and still outperforms VDSL Starting from 1 6 km 1 mi its performance is equal to ADSL2 ADSL like long reach performance is one of the...

Страница 127: ...over a network channel The greater the ratio the easier it is to identify and subsequently isolate and eliminate the source of noise 6 Symptom Connected the CO Router with CPE Router within 300 meter...

Страница 128: ...n causing the VDSL2 router not to link 1 NV 600LI 0 NV 600RI 2 Update the old hardware to latest firmware so that you can set the same tone mode for both CO and CPE router 8 Symptom VDSL2 web manageme...

Страница 129: ...ng test them in an alternate environment where you are sure that all the other components are functioning properly Transmission Mode The default method of selecting the transmission mode for RJ 45 por...

Страница 130: ...problem down by implementing the new changes one step at a time Ensure that cable distances and other physical aspects of the installation do not exceed recommendations System Integrity As a last reso...

Страница 131: ...a higher level of protection The table on the following offers clarity and an overview of the IP rules Table D 1 First Digit Protection grades for contact and foreign matter protection Digit Designat...

Страница 132: ...vertical on to the device 4 Protection against splash water Water splashing against the device from any direction may not have any harmful effect 5 Protection against water jets A jet of water aimed...

Страница 133: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation betwe...

Страница 134: ...FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment can generate use and radiat...

Страница 135: ...e environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning...

Страница 136: ...damage or which contain defects which are in any way attributable to improper installation or to alteration or repairs made or performed by any person not under control of the original owner The abov...

Страница 137: ...NV 600LI RI Managed Industrial Grade VDSL2 CO CPE Router USER S MANUAL Ver A4 136 Chinese SJ T 11364 2006 Pb Hg Cd Cr VI PBB PBDE SJ T 11364 2006 SJ T 11364 2006...

Отзывы: