Third edition, Feb. 2020
User Manual
NS388S
2U 24-bay(2.5") SAS (Host) to SAS/SATA (Disk) JBOD with 12Gb/s SAS Expander
Страница 1: ...Third edition Feb 2020 User Manual NS388S 2U 24 bay 2 5 SAS Host to SAS SATA Disk JBOD with 12Gb s SAS Expander...
Страница 2: ...s device appears to be malfunctioning contact Netstor Customer Service Do not drop the enclosures or any of its drive modules dropping or mishandling of the enclosure or drive modules may result in a...
Страница 3: ...up VT100 Screen 18 3 3 CLI Command HELP Command PASS Command LO Command GROUP Command SYS Command SPIN Command BU Command LSD Command SHOWLOGS Command CLEARLOGS Command FDL Command HSPC Command HDD Sl...
Страница 4: ...single HD mini SAS cable host connectivity the extra two HD mini SAS ports allow users to expand multiple 12Gbps SAS JBOD enclosures ensuring it the most cost effective storage expansion Before the in...
Страница 5: ...yout This section gives the layout of the panel and describes the procedures for setting up the NS388S enclosure 2 Activity indicator LED Blue HDD ready Flash Blue Access Flash Pink Rebuilding Red HDD...
Страница 6: ...mute buzzer beeping of fan PSU failure 5 Access LED Green Accessing is ready 6 Fault LED Red Linking is failed 11 LAN port 12 Terminal port for CLI con guration 13 Swappable fan 7 10 SAS Exp connecto...
Страница 7: ...ts button downward for the release of the lever until the lever pops out 3 Place a drive tray on a at and level surface and then attach the drive into the tray You must verify the heads of the four sc...
Страница 8: ...388S enclosure correctly until its lever appears to shut and then press the lever to close until it clicks to ensure that the drive module is within the enclosure 6 Repeat steps 2 to 5 for further dri...
Страница 9: ...s system functions can be managed via a computer running a VT 100 terminal emulation program or a VT 100 compatible terminal The provided internal cable converts the RS 232C signals from the RJ11 int...
Страница 10: ...ime Therefore when one 12G SAS Expander module accidentally fails the other host computer will still be able to access the data les stored on the Netstor storage in support of the failover The connect...
Страница 11: ...closure contains expander ports Expander ports can be attached to SAS initiator ports SAS and or SATA target ports and other expander ports The SAS RAID controller card supports daisy chain The number...
Страница 12: ...3 CLI feature of GR command that is used to associate the external port and the devices phys slot 11 The NS388S enclosure provides redundant power supply unit so connect one end of the two power cords...
Страница 13: ...You must complete the appropriate installation procedure before proceeding with the CLI function Whichever terminal emulation program is used must support the 1K XMODEM le transfer protocol The seria...
Страница 14: ...but for the most part they should be very similar The following setup procedure is an example of setting up VT100 Terminal in Windows O S using Hyper Terminal version 3 0 or higher For Windows 7 8 1...
Страница 15: ...15 Go Top Step 1 Open the Taskbar Start Programs Accessories Communications Hyper Terminal Hyper Terminal requires version 3 0 or higher Step 2 Open HYPERTRM EXE...
Страница 16: ...you prefer and then click OK Step 4 Select an appropriate connecting port and then click OK Step 5 Con gure the port parameter settings and then click OK Bits per second 115200 Data bits 8 Parity None...
Страница 17: ...roperties Step 7 Con gure the Connect To setting Step 8 Con gure the Settings items and then click OK Function arrow and ctrl keys act as Terminal Keys Backspace key sends Crtl H Emulation VT100 Telne...
Страница 18: ...r con fan alarm lsd Show status of each component on enclosure showlogs enter showlogs Show event log of SAS Expander enclosure clearlogs enter clearlogs Clear event log of SAS Expander enclosure fdl...
Страница 19: ...st Devices Status Usage Isd hdd temp volt curr pwr con fan alarm showlogs Show the current logs Usage showlogs DisplayMode hex detail default Clearlogs Clear the logs fdl File DownLoad Usage fdl code...
Страница 20: ...ord protection feature Once the password has been set the user can only monitor and access 12Gbps SAS JBOD enclosure setting by providing the correct password The password can accept max 8 chars and m...
Страница 21: ...te with one zone group Syntax gr dev GroupNo 1 ci cj ck Start Index D End Index D dev use drive slot index GroupNo groupno start from 1 to 8 max 8 groups ci cj ck external wide port connector i j k is...
Страница 22: ...16 Enter CLI CLI gr clr New Setting Default zone con guration Group 1 C0 C1 C2 C3 Slot 1 2 3 4 24 Clear group con guration ok CLI Clear the Zone group setting Syntax CLI gr clr Enter CLI CLI gr Curre...
Страница 23: ...CLI Command List CLI GLI gr on Enable zoning save zone con guration ok CLI Enable zoning Syntax CLI gr on Enter CLI CLI gr off Disable zoning save zone con guration ok CLI Disable zoning Syntax CLI gr...
Страница 24: ...40 Expander Chip Revision C1 Enclosure ID 538262B10000603F Chassis Type 2U Firmware Revision Information Firmware Revision 0010 Build Date Jan 23 2020 06 37 50 CLI 5 SYS Command The sys command is use...
Страница 25: ...S JBOD enclosure the ability to spin up the disk drives sequentially or in groups allowing the drives to come ready at the optimum time without straining the system power supply Staggering drive spin...
Страница 26: ...disable audible alarm function of the 12Gbps SAS JBOD enclosure Syntax CLI bu en dis Check buzzer status Syntax CLI bu Disable audible alarm function Syntax CLI bu dis After disable audible alarm func...
Страница 27: ...nown 00000000 00000000 HDD slot 14 13 16 0 0G 12 0G 3 0G Unknown 00000000 00000000 HDD slot 15 14 26 0 0G 12 0G 3 0G Unknown 00000000 00000000 HDD slot 16 15 39 0 0G 12 0G 3 0G Unknown 00000000 000000...
Страница 28: ...enp Bp Slot 22 Temp Bp Slot 23 Temp Bp Slot 24 Temp Psu 1 Temp Psu 2 Temp ID 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 CT C 62 40 22 22 22 23 22 23 22 24 24 2...
Страница 29: ...5 12 60 5 25 12 60 12 60 UVLMT 3 14 0 85 0 85 1 71 4 75 11 40 4 75 11 40 11 40 STATUS OK OK OK OK OK OK OK OK OK Note User can check voltage of expander chip backplane and PSUs VOLT V Current Voltage...
Страница 30: ...status CLI CLI lsd con Connector Element 0x19 NAME Connector00 Connector00 Connector00 Connector00 Connector01 Connector01 Connector01 Connector01 Connector02 Connector02 Connector02 Connector02 Conne...
Страница 31: ...Enclosure Fan 1 Enclosure Fan 2 PSU 1 Fan 1 PSU 1 Fan 2 PSU 2 Fan 1 PSU 2 Fan 2 ID 00 01 02 03 04 05 SPEED CODE 0 0 2 2 1 1 RPM 2960 1480 4000 4000 2000 2100 STATUS OK OK OK OK OK OK Show Audible Ala...
Страница 32: ...S Log ID 11 HDD Fault 9 SHOWLOGS Command The showlogs command allows you to display system event noti cations that have been generated by 12Gbps SAS JBOD enclosure Syntax CLI showlogs DisplayMode hex...
Страница 33: ...le in the following lename format 1 FW le CODE UT S3_24xx_YYY fw Note YYY is rmware revision ex UT S3_24xx_008 fw 2 MFG le MFGB UT S3_24xx_mfg_ZZZ bin Note ZZZ is SDK revision ex UT S3_24xx_mfg_008 bi...
Страница 34: ...dialog box prompts choose and the le in the directory then press send E If the transfer process complete the transferred data is updated Cold start expander Power cycle again to take effect D You can...
Страница 35: ...SAS expander MFGB region A One command to update rmware Step as follow B Issue download update command under CLI CLI fdl mfgb 0 CLI CLI fdl mfgb 0 Please Use XModem Protocol for File Transmission Use...
Страница 36: ...ON POWER ON POWER ON POWER ON POWER ON POWER ON POWER ON POWER ON POWER ON POWER ON POWER ON POWER ON CLI Command List E If the transfer process complete the transferred data is updated Cold start ex...
Страница 37: ...Power of HDD Slot 2 CLI hspc 2 on CLI hspc CLI CLI hspc HDD Slot Power Status SLOT 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 STATUS POWER ON POWER OFF POWER ON POWER ON...
Страница 38: ...uration CLI eth Set Ethernet IP Address Subnet Mask and Gateway CLI eth 192 168 100 206 255 255 255 0 192 168 100 253 When Ethernet port link is down CLI CLI eth Physical Address 38 26 2B 10 00 35 IP...
Страница 39: ...39 Go Top CLI Command List 14 RESET Command Reset 12Gbps SAS JBOD controller Syntax CLI reset CLI CLI reset...
Страница 40: ...on SAS Expander at rear of NS388S enclosure as Figure 4 1 to silence the beeping alert Answer When one of the PSU units breaks down power supply s buzzer will beep to alert the administrator how to mu...
Страница 41: ...41 Go Top Netstor Technology Co Ltd www netstor com tw 6F No 1 Alley 16 Lane 235 Baoqiao Rd Xindian District New Taipei City 231 45 Taiwan R O C sales netstor com tw 886 2 2917 1500...