22 | Netstor
•
Establishing the Connection for the RS-232 Port
The CLI function can be managed by using an ANSI/VT-100 compatible
terminal emulation program. The appropriate installation procedure
needs to be completed before proceeding to the CLI function. Whichever
terminal emulation program is used, it must support the 1K XMODEM file
transfer protocol.
The serial port on SAS Expander enclosure’s I/O shield can be used in
VT100 mode. The provided interface cable converts the RS232 signal of
the RJ-11 connector on enclosure into a 9-pin D-Sub male connector. A
VT-100 compatible terminal or a PC running a VT-100 terminal emulation
program to the serial port can access the text-based setup menu.
4.1 RS-232C Port Pin Assignment
To ensure proper communication between SAS Expander enclosure and
VT-100 Terminal Emulation, configure the VT100 terminal emulation
settings to the values below:
Содержание NS385S-8028
Страница 1: ......
Страница 29: ...26 Netstor Step 6 Open the file menu and select Properties Step 7 Configure the Connect To setting...
Страница 40: ...Note...