Installation Guide for the Model FE104 and Model FE108 Fast Ethernet Hubs
Fast Ethernet and Cabling Guidelines
C-5
Patch Panels and Cables
If you are using patch panels, make sure that they meet the 100BASE-T requirements. NETGEAR
recommends Category 5 UTP cable for all patch cables and work area cables to ensure that your
UTP patch cable rating meets or exceeds the distribution cable rating.
To wire patch panels, you need two Category 5 UTP cables with an RJ-45 connector at each end,
as shown in Figure C-3.
Key:
1 = RJ-45 connector
2 = Category 5 UTP patch cable
Figure C-3.
Category 5 UTP patch cable with male RJ-45 connector at each end
Note:
Flat “silver satin” telephone cable may have the same RJ-45 connector. However,
using telephone cable will result in excessive collisions and cause the attached port to be
partitioned or disconnected from the network.