Serial Output Stops After the BIOS
If serial output is shown for the BIOS but stops afterward, check the following items:
Terminal Speed
Ensure the terminal program is configured for the correct speed for the installed operating system.
(See
Device OS Serial Console Settings
Ensure the installed operating system is configured to activate the serial console
and that it is configured for the proper console (e.g.
ttyS1
in Linux). Consult the various operating install
guides on this site for further information.
Bootable Media
If booting from a USB flash drive, ensure that the drive was written correctly and contains a bootable
operating system image.
2.2 Reinstalling pfSense Plus Software
1. Please
to request access to the factory firmware by selecting
Firmware Access
as the
General Problem
and then select
Netgate 3100
for the platform. Make sure to include the serial number in the
ticket to expedite access.
Once the ticket is processed, the latest stable version of the firmware will be attached to the ticket, with a name
such as:
pfSense-plus-SG-3100-recover-22.05-RELEASE-armv7.img.gz
Note:
pfSense
®
Plus is preinstalled on Netgate appliances, which is optimally tuned for Netgate hardware and
contains features that cannot be found elsewhere, such as ZFS Boot Environments, OpenVPN DCO, and the
2. Write the image to a USB memstick. Locating the image and writing it to a USB memstick is covered in detail
under
3.
of the Netgate device.
4. Insert the memstick into the USB port and boot the system.
Tip:
The best practice is to
turn off
the device,
insert
the USB memstick, confirm
console access
, and
boot
the device.
Starting the recovery process requires
interrupting the boot process
very soon after the boot process begins.
5. When prompted, press any key to stop the autoboot process.
6. Type
run recovery
at the
Marvell>>
prompt and press
Enter
.
7. Enter the destination device or press the
Enter
key to accept the default value.
Note:
The onboard eMMC flash memory is always
mmcsd0
. If a M.2 SATA drive is installed in either slot, it
will be
ada0
.
Warning:
Only one M.2 SATA slot can be populated with a storage device. The device does not support
two M.2 SATA drives installed simultaneously.
© Copyright 2022 Rubicon Communications LLC
33
Содержание SG-3100
Страница 1: ...Security Gateway Manual SG 3100 Copyright 2022 Rubicon Communications LLC Jul 22 2022...
Страница 2: ...CONTENTS 1 Out of the Box 2 2 How To Guides 25 3 References 61 i...
Страница 10: ...Security Gateway Manual SG 3100 Fig 7 Read and Click Accept Copyright 2022 Rubicon Communications LLC 8...
Страница 17: ...Security Gateway Manual SG 3100 1 5 Hardware Specifications Copyright 2022 Rubicon Communications LLC 15...
Страница 36: ...Security Gateway Manual SG 3100 Copyright 2022 Rubicon Communications LLC 34...
Страница 39: ...Security Gateway Manual SG 3100 Fig 3 SG 3100 M 2 SATA Locations Copyright 2022 Rubicon Communications LLC 37...