HyPer 9HV IS User Manual Version 06

 

NetGain Motors, Inc.

 

Page 14 of 28

 

 

20.

 

On the motor encoder’s 4 Pin Ampseal connector - ensure the wires and connectors are restrained from 
movement within the installation area. Also ensure that these wires do not intersect or contact High 
Voltage cables or the motor’s field. Verify correct 

wiring of the encoder

1.

 

PIN1 is connected to K1-35  (+5V Out). 

2.

 

PIN2 is connected to K1-21 (Encoder Sin 1). 

3.

 

PIN3 is connected to K1-33 (Encoder Cos 1). 

4.

 

PIN4 is connected to K1-9  (Encoder I/O Ground). 

 

21.

 

Check that accessory voltage (12-24V) is connected to K1-24 (Key Switch In) when switching on the 
Key. This is the only wire on connector K1 that will see voltage from an outside source. 
 

22.

 

Check that Contactor Positive Coil is connected to K1-25 (Coil Return). 
 

23.

 

Check that Contactor Negative Coil is connected to K1-26 (Driver Output 1). 
 

24.

 

Connect Amp 35 pin connector to controller plug K1. 
 

25.

 

Couple the supplied 

Null Modem

 Serial Cable to the supplied Serial-USB adapter.  

 

26.

 

Connect USB end to PC loaded with SME Smartview Smarview Sys software.  
 

27.

 

Connect female serial end to X144 controller’s male serial K3 port.  
 

28.

 

Open 

SmartView DLR Sys

 software. 

 

29.

 

Select Connection type: Normal or Wired. Then select the Serial Port your device driver was installed 
on. 

1.

 

Your COM port number set is listed in the Windows Device Manager.  

2.

 

Verify that the COM port number is not already used by another software when SmartView is 
opened. 
 

30.

 

Verify vehicle is in Neutral with wheels suspended from the ground. Then switch on X144 controller via 
Key Switch, and ensure the controller’s Green or Red Status light is solid or blinking.  

1.

 

If Controller’s Status light is off, verify wiring.  

2.

 

If Smartview’s home screen options do not appear with a “Manage” block, verify steps 11-15 
are followed in order. 
 

31.

 

Once communicating with the Controller, install the downloaded 

.bin

 Firmware by clicking on: 

1.

 

Mange        Clone         Firmware Update 

2.

 

Browse the Firmware Path and select the most recent Firmware release, which you have 

downloaded

3.

 

Once this .bin file is selected and in the Firmware Path, Click 

PROGRAM.

 

 

32.

 

 Install your motor’s downloaded clone file by clicking on: 

Содержание HyPer 9HV IS

Страница 1: ...HyPer 9HV IS User Manual Version 06 NetGain Motors Inc Page 1 of 28 User Manual HyPer 9HV IS...

Страница 2: ...ver High Voltage Contacts and Key Switch In 10 Compact Display Pinout 11 Compact Display Mating Female Plug 11 Controller Specifications 12 Controller Communication 12 Controller EMC 12 Controller Saf...

Страница 3: ...8 X144 controller Temperature Derating 19 Signal Inputs and Outputs 20 Controller I O Table 20 Diagnostic Code Guide 23 Additional Support 28 Figure 1 Standard X144 Wiring Diagram 6 Figure 2 Standard...

Страница 4: ...uation find a knowledgeable person to advise you Make certain the motor and controller are disconnected from any power source before servicing If any doubt exists of the voltage that might exist measu...

Страница 5: ...king with motors Motors contain moving parts that could cause severe injury if the proper precautions are not taken Never touch an operating motor Do not defeat any safety circuits or safety devices U...

Страница 6: ...HyPer 9HV IS User Manual Version 06 NetGain Motors Inc Page 6 of 28 X144 Main Wiring Diagram X144 ONLY 12V 24V Key Switch For X1 wkring see HyPer 9 IS User Manual Figure 1 Standard X144 Wiring Diagram...

Страница 7: ...HV IS User Manual Version 06 NetGain Motors Inc Page 7 of 28 X144 K1 Wire Harness Pinout Figure 2 Standard X144 Pin Order Assignment Must Be Assigned See Motor Plug Wiring Instructions for Termination...

Страница 8: ...cable Slide heatshrink past the newly exposed foil and rest heatshrink on remaining jacket material for future adhesion 6 Slide diameter heatshrink over each of the 3 shileded twisted pairs Rest heats...

Страница 9: ...oder 4 Position Connector Pin Name Position 4 Encoder I O Ground K1 9 3 Encoder Cos 1 K1 33 2 Encoder Sin 1 K1 21 1 5V Out K1 35 Motor Thermistor Pin Positions Motor Thermistor 2 Position Connector Pi...

Страница 10: ...and Key Switch In X144 Main Contactor External PWM Terminal Name X144 Position X2 Driver Output 1 K1 26 X1 Coil Return K1 25 A2 Controller HV B Terminal A1 Precharge B Precharge This HV circuit should...

Страница 11: ...Name Position 8 12V Out K1 10 7 I O Ground K1 12 6 Not Connected N A 5 LIN BUS K1 15 4 Digital Input 1 TBD 3 Digital Input 2 TBD 2 Digital Input 3 TBD 1 Digital Input 4 TBD Figure 4 Compact Display Ma...

Страница 12: ...icle Owner takes full responsibility of the regulatory compliance of the vehicle system with the controller installed Controller Operating Environment Specifications Storage ambient temperature range...

Страница 13: ...le controller power is switched on Open High Voltage disconnect switch while working with High Voltage cables If a motor ever revs with no throttle applied turn off the key switch immediately Quicksta...

Страница 14: ...USB adapter 26 Connect USB end to PC loaded with SME Smartview Smarview Sys software 27 Connect female serial end to X144 controller s male serial K3 port 28 Open SmartView DLR Sys software 29 Select...

Страница 15: ...00mV please verify wiring c If a throttle other than NetGain s HEPA is being used a custom throttle map is required to match your throttle Please refer to Post Startup Steps to adjust the Throttle Map...

Страница 16: ...motor 1 Select the Forward Direction 2 Press the Throttle and notice the Motor driving 3 Press the Brake and notice the Motor braking 36 If the Motor is in Blocked Rotor condition maximum Current and...

Страница 17: ...Mapping Dynamic Brake Pedal Regen is pre programmed in all HyPer 9HV Clone files To utilize Dynamic Brake Pedal Regen a Brake Pressure Transducer must be installed in the system This Transducer sends...

Страница 18: ...er from any DC supply with limits between 62V 132V The controller can estimate a battery s state of charge based off a specified Voltage Map Follow the steps below to Map your battery pack 1 On the Sm...

Страница 19: ...erheating the controller is programmed to derate power based on its heatsink temperature Additional cooling methods such as Liquid Cooling may be required if your controller is overheating under norma...

Страница 20: ...Negative Logic Supply 2 CAN L CAN BUS CAN BUS 1 MBit s max CAN L No internal termination resistor 3 CAN L RES CAN BUS Connected to CAN L with a series 120Ohm Termination resistor 4 DIGITAL INPUT 1 Dig...

Страница 21: ...ASSIGNED 18 DIGITAL IN 7 Digital Input VL 2V VH 4 5V Resistor pull down active high or pull up active low ON rated voltage 12V 24V TO BE ASSIGNED 19 DIGITAL IN 8 Digital Input VL 2V VH 4 5V Resistor p...

Страница 22: ...low Internal diode to coil return Main Contactor Brake Valve 30 DIGITAL OUTPUT 1 Digital Output active low No internal diode to coil return Buzzer Fan ON OFF valve 31 DIGITAL OUTPUT 2 Digital Output a...

Страница 23: ...des please refer to the Diagnose tier of smartview s Help section and click on any Fault name for a troubleshooting guide Level anomalous working conditions are indicated by different alarm levels cla...

Страница 24: ...rter 2 Over Temperature Inverter 2 power module temperature is above 100 C Blocking 10 Inverter 1 High Temperature Inverter 1 power module temperature is above 80 C Limiting 11 Inverter 2 High Tempera...

Страница 25: ...fined by the user via related parameter Limiting 27 Microprocessor Over Temperature Microprocessor temperature is above 125 C Blocking 28 5V Supply Failure 5V supply is outside the 5V 10 range Blockin...

Страница 26: ...after a controlled stop procedure Warning 47 Traction Throttle Fault A fault condition of traction throttle is detected Stopping 48 Hydraulic Throttle Fault A fault condition of hydraulic pump throttl...

Страница 27: ...ro Failed At least one node of the network could be wrong configured or switched off Blocking 74 CO Synchro Lost At least one node of the network could be wrong configured or switched off during opera...

Страница 28: ...rdware Fault 2 Internal Error Blocking 105 Internal Hardware Fault 3 Internal Error Blocking 106 Internal Hardware Fault 4 Internal Error Blocking 107 Internal Software Fault 4 Internal Error Blocking...

Отзывы: