2.10 System Installation
2.10.1 Setting up a DSL Concentrator
Before installation, ensure all cards are inserted in the correct position and fit into the chassis. Then complete
the following procedures to install a DSL Concentrator.
Figure 2-1 Setting Up A Chassis
STEP 1:
Use a DB9 connection cable to connect the PC COM port to the AMCU console port.
STEP 2:
Make sure the chassis ID DIP switch is set to “all on”.
STEP 3:
Use an RJ45 connection cable to connect the LAN and the AMCU LAN port for remote SNMP
configuration.
STEP 4:
Connect the office alarm connectors to an external visible or audible alarm device (if required).
STEP 5:
Connect either or both of the two -48VDC power connectors to the power source.
RJ45 LAN Cable
(Ethernet cable should
be cross-over type)
RS-232 cross-over cable
NCT-1000
-48V PG FG
-48V PG FG
B
A
AU_ALM VI_ALM
FUSE B
FUSE A
Shelf ID
FG DG
75 olm
IN
OUT
120 ohm
Ethernet 1 Ethernet 2
Management
-48V PG FG
-48V PG FG
B
A
FUSE B
FUSE A
Ethernet 1
Ethernet 2
Management
AU_ALM VI_ALM
Shelf ID
FG DG
75 olm
IN
OUT
RJ45 LAN Cable
(Ethernet cable should
be cross-over type)
RS-232 cross-over cable
NCT-1020
Содержание NCT-1000
Страница 1: ......
Страница 7: ...NCT 1000 NCT 1020 User Guide 7 YML836 Rev2 Application 2...
Страница 69: ...NCT 1000 NCT 1020 User Guide 69 YML836 Rev2 6 3 Exiting the AES G Click the Exit tab to exit this unit...
Страница 105: ...NCT 1000 NCT 1020 User Guide 105 YML836 Rev2 PART III APPENDICES...
Страница 138: ...138 NCT 1000 NCT 1020 User Guide YML836 Rev2...
Страница 139: ......