If the system-level diagnostics
tests…
Then…
Were completed without any
failures
a. Clear the status logs:
sldiag device clearstatus
b. Verify that the log was cleared:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c. Exit Maintenance mode:
halt
The system displays the LOADER prompt.
You have completed system-level diagnostics.
Resulted in some test failures
Determine the cause of the problem.
a. Exit Maintenance mode:
halt
b. Perform a clean shutdown, and then disconnect the power
supplies.
c. Verify that you have observed all of the considerations identified
for running system-level diagnostics, that cables are securely
connected, and that hardware components are properly installed
in the storage system.
d. Reconnect the power supplies, and then power on the storage
system.
e. Rerun the system-level diagnostics test.
Recable the system and reassign disks - FAS8200
Continue the replacement procedure by recabling the storage and confirming disk
reassignment.
Step 1: Recable the system
After running diagnostics, you must recable the controller module’s storage and network
connections.
Steps
1. Recable the system.
2. Verify that the cabling is correct by using
.
a. Download and install Config Advisor.
b. Enter the information for the target system, and then click Collect Data.
69