background image

220-0000070 rev01

UIM-T1

T1 Uplink Interface Module

Installation

1. Unpack and inspect the equipment.

The following components should be included:

          1 UIM-T1
          4 #6 Phillips Panhead Internal Locking Screws
          2 #6 Phillips Beige Flathead Screws

If there is any visible damage, do not attempt to connect the device. Contact Customer Support at 1-
877-638-2638 (001-603-427-0600 for international customers) or [email protected].

2. Verify switch configuration.

Ensure that the DIP switches on the UIM-T1 circuit board are positioned correctly (according to desired 
configurations) prior to installing the UIM-T1 on a Multiplexer Uplink Module or in a Mini DSLAM. There 
are eight DIP switches located on the top side of the circuit board, opposite the faceplate. Switches are 
numbered from left to right, starting with Switch #1 on the left and ending with Switch #8 on the right. 
Switches 1-2 and 7-8 are not used. Configurations for switches 3-6 are as follows:

Installation Instructions

 

CAUTION

Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when 
handling this equipment. 

Frame Type & Line Coding 
Switch Configuration

 

Switch #3 Frame Type Switch #4 Line Coding

down

ESF

down

B8ZS

up

SF

up

AMI

  

SF = Super Frame
ESF = Extended Super Frame
B8ZS = Bipolar with 8 Zero Substitution
AMI = Alternate Mark Inversion

  

Transmit Line Buildout 
Switch Configuration

 

Switch #5
LBO Low

Switch #6
LBO High

Line Attenuation

down

down

0 dB

up

down

-7.5 dB

down

up

-15 dB

up

up

-22.5 dB

  

  

Отзывы: