Net Optics 10/100/1000 Base Tap Скачать руководство пользователя страница 8

Gig Zero Delay Tap & 10/100/1000BaseT Tap

5

Product Diagrams

Figure 1: 

Front Panel, Gig Zero Delay Taps (TP-CU3-ZD, TP-CU3-ZD-DC)

Figure 2: 

Front Panel, 10/100/1000BaseT Taps (TP-CU3, TP-CU3-DC)

F

igure 3:

 Rear Panel AC (external transformer “brick”) power models

Figure 4:

 Rear Panel DC power model TP-CU3-DC

- +

- +

For use with -48 only

- +

- +

Terminal Blocks

DIP Switch

OFF

1

3 4 5 6 7 8

2

Figure 5:

 Rear Panel DC power model TP-CU3-ZD-DC

Monitor A & B

Network A & B 

Power

LEDs

®

www.netoptics.com

Network

Monitor

10

100

1000

LINK
ACT

1

2

Zero Delay

Zero Delay

A

A

B

B

Power DC Jacks

Retainer Clip

DIP Switch

OFF

1

3 4 5 6 7 8

2

- +

- +

For use with -48 only

- +

- +

Terminal Block

DIP Switch

on side

Terminal Block

Monitor A & B

Network A & B 

Power

LEDs

®

www.netoptics.com

Monitor

Network

10

100

1000

LINK
ACT

1

2

Full Duplex Tap

Full Duplex Tap

A

A

B

B

Содержание 10/100/1000 Base Tap

Страница 1: ...Installation Guide for Gig Zero Delay Tap and 10 100 1000BaseT Tap 800 0150 001 Rev G PUBTPCU3ZDU 2 11...

Страница 2: ...d to assist with installing Net Optics products into your network Trademarks and Copyrights 2011 by Net Optics Inc Net Optics Gig Zero Delay and Link Fault DetectM are registered trade marks of Net Op...

Страница 3: ...npacking and Inspection 4 Product Diagrams 5 DC Terminal Blocks 6 LED Indicators 7 Link Fault DetectTM 7 Cabling Guidelines 7 Connecting to the Monitoring Device 9 DIP Switch Settings 10 Specification...

Страница 4: ...00 BaseT Taps establish permanent passive access ports without introducing a point of failure or disturbing other network connections The Gig Zero Delay Tap either auto negotiates communication or use...

Страница 5: ...ly switches to the backup power source Power LEDs on the front of the Tap indicate the current power source Warning ________________________________________________________ TP CU3 ZD and TP CU3 ZD DC...

Страница 6: ...toring uptime Fully IEEE 802 3 compliant Fully RoHS compliant Ease of Use LED indicators show redundant power and link status DIP switches select auto negotiation of fixed speed and duplexing settings...

Страница 7: ...power cords TP CU3 ZD and TP CU3 only 1 retainer clip TP CU3 ZD and TP CU3 only 1 network cable 3 meter straight through purple 1 network cable 3 meter cross over green 2 monitor cables 3 meter strai...

Страница 8: ...e with 48 only Terminal Blocks DIP Switch OFF 1 3 4 5 6 7 8 2 Figure 5 Rear Panel DC power model TP CU3 ZD DC Monitor A B Network A B Power LEDs www netoptics com Network Monitor 10 100 1000 LINK ACT...

Страница 9: ...Just pull to unplug the removable part and push it back in to reconnect it To connect the power wires insert a wire into a socket and tighen the screw to hold it in place Figure 6 Two piece DC termina...

Страница 10: ...Fault Detect requires that both sides of the full duplex link and communicating at the same speed Cabling Guidelines If both of the devices connected to the Tap network ports are 10 100BaseT devices t...

Страница 11: ...pport Automatic MDI MDI X Configuration then the positions of the transmit and receive pins cannot be detected automatically and straight through or crossover cables are required as specified in the p...

Страница 12: ...e ______________________________________________________________________ 2 Connect Monitor Port A to the appropriate port on the monitoring device using a CAT5e straight through cable This cable sends...

Страница 13: ...is active for all ports Half duplex is active for all ports If switch 2 is ON this switch is ignored 7 Reserved 8 OFF MUST BE OFF NOTE To activate push buttons UP This diagram shows all segments in t...

Страница 14: ...utput 12V 1 5A TP CU3 and TP CU3 DC 12V 3A TP CU3 ZD and TP CU3 ZD DC 48V Power Supply Input 48V DC typical 36V DC min 75V DC max DC Receptacle Terminal peak 12 14 gauge wire Power Over Ethernet POE F...

Страница 15: ...Gig Zero Delay Tap 10 100 1000BaseT Tap 12 Connectors 2 RJ45 8 pin connectors monitor ports 2 RJ45 8 pin connectors network ports Certifications Fully RoHS compliant Fully IEEE 802 3 compliant...

Страница 16: ...Gig Zero Delay Tap 10 100 1000BaseT Tap 13 19 00 9 90 1 10 5 55 1 73 10 32 25 5 14 TP CU3 ZD Dimensions...

Страница 17: ...Gig Zero Delay Tap 10 100 1000BaseT Tap 14 5 55 1 10 6 40 19 00 1 73 5 14 TP CU3 Dimensions...

Страница 18: ...s WEEE compliance Indicates CE compliance Indicates RoHS compliance Indicates C Tick compliance Indicates VCCI compliance Indicates MET compliance U S A safety RF VW O CH 1 M4b 4cb F 23d6 A B 23456 78...

Страница 19: ...s section and speak with our technical service personnel They may provide you with an RMAnumber which must accompany any returned product Return the product in its original shipping container or equiv...

Страница 20: ...2011 by Net Optics Inc All Rights Reserved www netoptics com...

Отзывы: