Net Optics 10/100/1000 Base Tap Скачать руководство пользователя страница 7

Gig Zero Delay Tap & 10/100/1000BaseT Tap

4

About This Guide

This guide explains how to install the Gig Zero Delay Tap and the 

10/100/1000BaseT Tap. Please read the Guide before attempting to install 

the device.

This guide covers the following models: 
•  TP-CU3-ZD 

10/100/1000 Tap with Zero Delay

•  TP-CU3-ZD-DC  10/100/1000 Tap with Zero Delay, -48V DC power

•  TP-CU3 

10/100/1000 Tap

•  TP-CU3-DC 

10/100/1000 Tap , -48V DC power

Unpacking and Inspection

Carefully unpack the Gig Zero Delay Tap and check for damaged or   missing 

parts. The Tap ships with the following:

•  (1) Tap device

•  (2) power supplies (TP-CU3-ZD and TP-CU3 only)

•  (2) power cords (TP-CU3-ZD and TP-CU3 only)

•  (1) retainer clip (TP-CU3-ZD and TP-CU3 only)

•  (1) network cable, 3 meter, straight-through (purple) 

•  (1) network cable, 3 meter,  cross-over (green)

•  (2) monitor cables, 3 meter, straight-through (purple)

•  (1) Installation Guide

You may have also ordered a panel for rack mounting and an extended warranty. 

Carefully check the packing slip against parts received. If any part is missing or 

damaged, contact Net Optics Customer Service immediately.

Warning! ____________________________________________________________

For the TP-CU3-ZD and TP-CU3 models, use only the power supplies pro-

vided by Net Optics for use with this product. Use of other power supplies may 

result in a safety hazard that could cause damage or injury.

_______________________________________________________________________

Содержание 10/100/1000 Base Tap

Страница 1: ...Installation Guide for Gig Zero Delay Tap and 10 100 1000BaseT Tap 800 0150 001 Rev G PUBTPCU3ZDU 2 11...

Страница 2: ...d to assist with installing Net Optics products into your network Trademarks and Copyrights 2011 by Net Optics Inc Net Optics Gig Zero Delay and Link Fault DetectM are registered trade marks of Net Op...

Страница 3: ...npacking and Inspection 4 Product Diagrams 5 DC Terminal Blocks 6 LED Indicators 7 Link Fault DetectTM 7 Cabling Guidelines 7 Connecting to the Monitoring Device 9 DIP Switch Settings 10 Specification...

Страница 4: ...00 BaseT Taps establish permanent passive access ports without introducing a point of failure or disturbing other network connections The Gig Zero Delay Tap either auto negotiates communication or use...

Страница 5: ...ly switches to the backup power source Power LEDs on the front of the Tap indicate the current power source Warning ________________________________________________________ TP CU3 ZD and TP CU3 ZD DC...

Страница 6: ...toring uptime Fully IEEE 802 3 compliant Fully RoHS compliant Ease of Use LED indicators show redundant power and link status DIP switches select auto negotiation of fixed speed and duplexing settings...

Страница 7: ...power cords TP CU3 ZD and TP CU3 only 1 retainer clip TP CU3 ZD and TP CU3 only 1 network cable 3 meter straight through purple 1 network cable 3 meter cross over green 2 monitor cables 3 meter strai...

Страница 8: ...e with 48 only Terminal Blocks DIP Switch OFF 1 3 4 5 6 7 8 2 Figure 5 Rear Panel DC power model TP CU3 ZD DC Monitor A B Network A B Power LEDs www netoptics com Network Monitor 10 100 1000 LINK ACT...

Страница 9: ...Just pull to unplug the removable part and push it back in to reconnect it To connect the power wires insert a wire into a socket and tighen the screw to hold it in place Figure 6 Two piece DC termina...

Страница 10: ...Fault Detect requires that both sides of the full duplex link and communicating at the same speed Cabling Guidelines If both of the devices connected to the Tap network ports are 10 100BaseT devices t...

Страница 11: ...pport Automatic MDI MDI X Configuration then the positions of the transmit and receive pins cannot be detected automatically and straight through or crossover cables are required as specified in the p...

Страница 12: ...e ______________________________________________________________________ 2 Connect Monitor Port A to the appropriate port on the monitoring device using a CAT5e straight through cable This cable sends...

Страница 13: ...is active for all ports Half duplex is active for all ports If switch 2 is ON this switch is ignored 7 Reserved 8 OFF MUST BE OFF NOTE To activate push buttons UP This diagram shows all segments in t...

Страница 14: ...utput 12V 1 5A TP CU3 and TP CU3 DC 12V 3A TP CU3 ZD and TP CU3 ZD DC 48V Power Supply Input 48V DC typical 36V DC min 75V DC max DC Receptacle Terminal peak 12 14 gauge wire Power Over Ethernet POE F...

Страница 15: ...Gig Zero Delay Tap 10 100 1000BaseT Tap 12 Connectors 2 RJ45 8 pin connectors monitor ports 2 RJ45 8 pin connectors network ports Certifications Fully RoHS compliant Fully IEEE 802 3 compliant...

Страница 16: ...Gig Zero Delay Tap 10 100 1000BaseT Tap 13 19 00 9 90 1 10 5 55 1 73 10 32 25 5 14 TP CU3 ZD Dimensions...

Страница 17: ...Gig Zero Delay Tap 10 100 1000BaseT Tap 14 5 55 1 10 6 40 19 00 1 73 5 14 TP CU3 Dimensions...

Страница 18: ...s WEEE compliance Indicates CE compliance Indicates RoHS compliance Indicates C Tick compliance Indicates VCCI compliance Indicates MET compliance U S A safety RF VW O CH 1 M4b 4cb F 23d6 A B 23456 78...

Страница 19: ...s section and speak with our technical service personnel They may provide you with an RMAnumber which must accompany any returned product Return the product in its original shipping container or equiv...

Страница 20: ...2011 by Net Optics Inc All Rights Reserved www netoptics com...

Отзывы: