CONNECTING THE GAS SUPPLY LINE
WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this
appliance.
The gas line connection may be made using 3/8 " rigid tubing or an approved flex connector. When using
copper or flex connectors, use only fittings approved for gas connections. The gas control inlet is
⅜
" NPT.
Upon connection, mark the appropriate fuel type on the CSA rating label.
There must be a gas shutoff between the stove and the supply.
Since some municipalities have additional local codes it is always best to consult your local authorities and
the CAN/CGA-B149.1 Installation Code. For USA gas installations follow either local codes or the current
edition of the National Fuel Gas Code ANSI.Z223.1.
Test to confirm manifold pressures as shown in the table on page 3.
The stove and its individual shutoff valve must be disconnected from the gas supply piping during any
pressure testing of that system
at test pressures in excess of ½ psi (3.5 kPa).
The stove must be isolated from the gas piping system by closing its individual shutoff valve during any
pressure testing of the gas supply piping system at test pressure equal or less than ½ psi (3.5 kPa).
Always check for gas leaks with a mild soap and water solution. Do not use an open flame for gas leak
testing.