sleeP

Sets the detector’s re-trigger interval.

2sec

 The detector will “sleep” for 2 seconds 

after being triggered. 

 

This  mode  should  only  be  used  for 
walk-testing coverage as it will reduce 
the battery life if left on permanently.

2min

 Normal operating mode. The detector 

will  “sleep”  for  2  minutes  after  being 
triggered. (Default) 

This battery-saving mode limits unwanted radio 
transmissions  by  waiting  until  there  has  been 
no detectable movement in the area for at least 
2  minutes  before  it  will  trigger  and  transmit  a 
new alarm.
The Sleep time applies only to alarm transmis-
sions.  The  night-light  will  turn  on  every  time 
the  detector  detects  movement  (if  enabled  by 
the LIGHT switch and if the ambient lighting is 
suitably low).

lIght level

Sets the light level at which LUX’s ambient light 
sensor will enable the night-light.

DRK

  The  night-light  will  operate  only  when 

the ambient lighting is very low or near 
total darkness. (Default)

LHT

  The  night-light  will  operate  when  the 

ambient lighting is semi-dark.

settIngs

Ness LUX custom settings are set by turning dipswitches 1-6 on or off. The dipswitches are easily ac-
cessible by removing LUX from the back housing.
Use a small screwdriver or pen tip to set the switches.

lIght

Enable/Disable the night-light.

ON

  The  night-light  will  function  and  draw 

power from battery A. (Default)

OFF

 The night-light is disabled.

Note: If battery A is not installed or is flat the night-
light will not work regardless of the switch setting.

alarM led

Enable/Disable the blue Alarm LED.
Note. The blue LED will always operate in Test 
Mode regardless of this switch setting.

ON

 The Alarm LED is enabled. (Default)

OFF

 The Alarm LED is disabled.

Pulse

Sets the detector’s pulse count.

1–2

 1–2 Pulses or walk steps should cause 

an alarm. (Default)

3–4

 3–4 Pulses or walk steps should cause 

an alarm. 

 

this setting is recommended for one 
pet over 10kg or multiple pets of any 
size.

range

Sets the maximum detection range.

HI

 15m x 15m max. coverage.

LOW

  12m  x  12m  max.  coverage.  recom-

mended setting. (Default)

2sec 2min SLEEP

DRK

LHT LIGHT LEVEL

ON

OFF LIGHT

ON

OFF ALARM LED

1-2

3-4 PULSE

HI

LOW RANGE

Содержание Lux

Страница 1: ...Adjustable Range High R F and E S D immunity High white light immunity SAWR stabilised radio transmitter Capsule design with sealed electronics Front cover tamper protection Long life Lithium batteries supplied Low battery warning signal Hourly Supervision radio signals Includes wall mounting bracket Optional ceiling bracket available ...

Страница 2: ...hile the built in ambient light sensor helps save power by enabling the night light only in the dark Ness LUX s capsule design protects sensitive electronic components and provides easy access to the dipswitches and batteries LUX PET AWARE PIR s unique Opposing Fields lens technology ensures high sensitivity to large targets and excellent rejection of household pets This gives it a superior abilit...

Страница 3: ...ct Wall Mounting If mounting direct to the wall without a bracket first fit the blanking plug supplied to seal the bracket mounting hole in the back housing Drilling points for flat wall or corner mounting are provided on the inside of the housing Separating the Back Housing Remove the LUX capsule from the back housing to access the batteries and switches FIG 2 Installation of the Standard Swivel ...

Страница 4: ...dity which may cause condensation on the lens Always install the detector away from metal surfaces which may shield radio transmissions Before permanently mounting the detector it is recommended that you conduct a radio test with the detector temporarily mounted in the intended position Use the signal strength meter on the alarm panel as a guide to the best mounting position Often a small change i...

Страница 5: ...to the environment 8 Walk test the coverage by walking slowly across the protected area The blue alarm LED indicates alarm detection and radio transmission During Walk Test Mode the white night light LED will also turn on unless disabled by the LIGHT dipswitch Adjust the coverage as required by tilting the detector horizontally or vertically on the swivel bracket If LUX is direct mounted without a...

Страница 6: ...ll operate when the ambient lighting is semi dark Settings Ness LUX custom settings are set by turning dipswitches 1 6 on or off The dipswitches are easily ac cessible by removing LUX from the back housing Use a small screwdriver or pen tip to set the switches Light Enable Disable the night light ON The night light will function and draw power from battery A Default OFF The night light is disabled...

Страница 7: ...at the same time Use only CR123A 3V Lithium Part No 142 028 Batteries are sold individually Battery A Battery B Model LUX PIR Test Mode is 1 hour 2 sec 2min SLEEP DRK LHT Light Level ON OFF Light ON OFF Alarm LED 1 2 3 4 Pulse HI LOW Range Battery A Battery B Correct polarity Tamper Signal The onboard tamper switch transmits a Tamper signal when the detector is removed from the back housing Your N...

Страница 8: ...s cordless phones computers TVs and other electronic devices may reduce the range performance While such occurrences are unusual they are possible In this case it may be necessary to either increase the physical separation between the Ness receiver and other devices or if possible change the radio frequency or channel of the other devices 2 Unauthorised tampering physical damage electrical interru...

Отзывы: