background image

4

MountIng locatIon

The  Ness  LUX  PET  Radio  PIR  is  designed  for 
indoor  use  only  and  can  be  installed  in  wall  or 
corner mount locations.
The Standard Swivel Bracket supplied allows wall 
mount installation with vertical tilt and horizontal 
swivel for adjusting coverage to suit the chosen 
mounting height. 
The optional Deluxe Swivel Bracket allows LUX to 
be ceiling mounting.
LUX can also be installed direct to the wall without 
a bracket. In this case, the mounting height should 
be carefully chosen to provide the correct detec-
tion coverage for the room size.
Always ensure the detector has a clear line of sight 
of the area to be protected as infra-red energy does 
not pass through solid objects, (including glass).
Mount the detector in a location where an intruder 
is most likely to walk across the coverage pattern. 
Corner mounting usually gives the best detection 
coverage.
As with all PIR detectors, it is advisable to choose 
mounting  positions  which  avoid  direct  sunlight, 
heating  or  cooling  sources  and  avoid  areas  of 
high  humidity  which  may  cause  condensation 
on the lens.

Always  install  the  detector  away  from  metal 
surfaces  which  may  shield  radio  transmissions. 
Before  permanently  mounting  the  detector,  it  is 
recommended that you conduct a radio test with 
the detector temporarily mounted in the intended 
position.
Use the signal strength meter on the alarm panel 
as a guide to the best mounting position. Often, 
a small change in position can have a dramatic 
effect on radio performance due to environmental 
effects on radio signals.

Pet rejectIon

The Ness LUX PET Radio PIR should be installed 
at heights between 2.1m and 2.4m. 
The lower detection zones are optimised to reject 
pet detection while the upper detection zones are 
optimised for detecting humans.
If using the Standard Swivel Bracket, ensure that 
LUX PET is not tilted downwards to prevent the 
upper detection zones from intersecting the floor. 

  Installing  the  detector  lower  than  2.1metres 

may result in false detection of pets.

 Tilting the coverage downwards may result in 

false detection of pets.

Install at least 2.1m away from furniture to prevent detection of climbing pets.

correct. upper zones are off the floor.

wrong. too much tilt means the upper 
zones will detect pets.

2.4m max.

2.1m min.

Содержание Lux

Страница 1: ...Adjustable Range High R F and E S D immunity High white light immunity SAWR stabilised radio transmitter Capsule design with sealed electronics Front cover tamper protection Long life Lithium batteries supplied Low battery warning signal Hourly Supervision radio signals Includes wall mounting bracket Optional ceiling bracket available ...

Страница 2: ...hile the built in ambient light sensor helps save power by enabling the night light only in the dark Ness LUX s capsule design protects sensitive electronic components and provides easy access to the dipswitches and batteries LUX PET AWARE PIR s unique Opposing Fields lens technology ensures high sensitivity to large targets and excellent rejection of household pets This gives it a superior abilit...

Страница 3: ...ct Wall Mounting If mounting direct to the wall without a bracket first fit the blanking plug supplied to seal the bracket mounting hole in the back housing Drilling points for flat wall or corner mounting are provided on the inside of the housing Separating the Back Housing Remove the LUX capsule from the back housing to access the batteries and switches FIG 2 Installation of the Standard Swivel ...

Страница 4: ...dity which may cause condensation on the lens Always install the detector away from metal surfaces which may shield radio transmissions Before permanently mounting the detector it is recommended that you conduct a radio test with the detector temporarily mounted in the intended position Use the signal strength meter on the alarm panel as a guide to the best mounting position Often a small change i...

Страница 5: ...to the environment 8 Walk test the coverage by walking slowly across the protected area The blue alarm LED indicates alarm detection and radio transmission During Walk Test Mode the white night light LED will also turn on unless disabled by the LIGHT dipswitch Adjust the coverage as required by tilting the detector horizontally or vertically on the swivel bracket If LUX is direct mounted without a...

Страница 6: ...ll operate when the ambient lighting is semi dark Settings Ness LUX custom settings are set by turning dipswitches 1 6 on or off The dipswitches are easily ac cessible by removing LUX from the back housing Use a small screwdriver or pen tip to set the switches Light Enable Disable the night light ON The night light will function and draw power from battery A Default OFF The night light is disabled...

Страница 7: ...at the same time Use only CR123A 3V Lithium Part No 142 028 Batteries are sold individually Battery A Battery B Model LUX PIR Test Mode is 1 hour 2 sec 2min SLEEP DRK LHT Light Level ON OFF Light ON OFF Alarm LED 1 2 3 4 Pulse HI LOW Range Battery A Battery B Correct polarity Tamper Signal The onboard tamper switch transmits a Tamper signal when the detector is removed from the back housing Your N...

Страница 8: ...s cordless phones computers TVs and other electronic devices may reduce the range performance While such occurrences are unusual they are possible In this case it may be necessary to either increase the physical separation between the Ness receiver and other devices or if possible change the radio frequency or channel of the other devices 2 Unauthorised tampering physical damage electrical interru...

Отзывы: