saturn programmIng
For the Installer
7
P126e
D8x/D16x PaneL / KeyPaD oPtIonS
Program moDe LeVeL
Installer Program mode / NessComms
V5.3 or later.
FaCtory DeFaULt
All off.
noteS
• One or all options can be enabled.
• To operate Saturn double key
functions press and hold the matching
keys for at least 1.5sec. (In normal
operating mode only, keypad pairs are
disabled in programming mode).
reLateD oPtIonS
P61E 5E-8E Keypad PANIC outputs
P75E 2E Report MEDICAL alarms
P75E 3E Report PANIC alarms
P75E 4E Report FIRE alarms
The Saturn keypad has keypad pairs for Panic,
Fire and Medical alarms and special chime
modes.
These program options are available only in
D8x/D16x V6 and later.
TO PROGRAM
1. Press P126e.
2. Press 1e-5e to turn an option ON or OFF.
1E ON, enables double key PANIC.
2E ON, enables double key FIRE.
3E ON, enables double key MEDICAL.
4E ON, enables Entry Chime in Day mode.
Used to announce entry in Day mode.
5E ON, enable Chime in Saturn keypads.
Used to announce entry in Monitor mode.
Programming
Programming option P126E in the D8x/D16x V6 and later control panels enable the Saturn
KP Panic, Medical and Fire alarms as well as the Chime mode. Saturn can also be used with
previous versions of D8x/D16x panels but these Saturn options will not be available.