Citiz service manual
103
F U N C T I O N T E S T S
9.3
Measure flow rate
The pressure adapter
must sit firmly in the
capsule bay.
1) Fill and insert water tank.
2) Open closing handle.
3) Insert connecting unit of pressure
adapter into capsule bay. Push back
sealing cone into capsule cage.
4) Insert fixation unit of pressure adapter
into capsule bay.
5) Press down operating lever.
6) Connect pressure hose to pressure
tester.
7) Place a measuring cup under the drain
hose of the pressure tester.
2.
1.
3.
4.
5.
6.
7.
Содержание EF 451 C 111
Страница 19: ...Citiz service manual 19 T E C H N I C A L D A T A Rating plates Citiz machine partners...
Страница 20: ...Citiz service manual 20 T E C H N I C A L D A T A Rating plates Citiz milk machine partners...
Страница 59: ...Citiz service manual 59 R E P A I R S At the bottom side of platform loosen 5 screws 41 oval shaped head 41...
Страница 98: ...Citiz service manual 98 R E P A I R S Wiring diagram 220 V 240 V IEC model Citiz milk EF 467 468...
Страница 99: ...Citiz service manual 99 R E P A I R S Wiring diagram 120 V 127 V IEC Mexico model Citiz EF 451 452...
Страница 100: ...Citiz service manual 100 R E P A I R S Wiring diagram 120 V 127 V IEC model Citiz milk EF 467 468...
Страница 118: ...Citiz service manual 118 E X P L O S I O N D R A W I N G S...
Страница 121: ...Citiz service manual 121 E X P L O S I O N D R A W I N G S 10 3 Model Citiz EF 452 D111...
Страница 122: ...Citiz service manual 122 E X P L O S I O N D R A W I N G S...
Страница 125: ...Citiz service manual 125 E X P L O S I O N D R A W I N G S 10 5 Model Citiz EF 467 C121...
Страница 126: ...Citiz service manual 126 E X P L O S I O N D R A W I N G S...
Страница 129: ...Citiz service manual 129 E X P L O S I O N D R A W I N G S 10 7 Model Citiz EF 468 D121...
Страница 130: ...Citiz service manual 130 E X P L O S I O N D R A W I N G S...
Страница 133: ...Citiz service manual 133 E X P L O S I O N D R A W I N G S...