background image

The devices should be transported packaged, in containers, closed railway cars, heated and air-
tight compartments of aircraft and holds and by trucks with rain and snow protection for  any 
distances at temperatures from -50°C to +50°C and relative humidity of 100% at 25°C. 

Average service life is 5 years min. 

12.

Disposal

At the end of the service life the device is subject to disposal. The device does not pose a hazard
to human health and environment. The device does not contain any non-ferrous and precious
metals.

13.

Manufacturer’s warranty

Guaranteed  storage  life  is  6  months  from  the  manufacturing  date  (the  last  6  figures  in  the
product serial number, for example: 191117 – November 19, 2017).

Guarantee service life is 24 months from the date of sale. 

With the note of sale absent – from the manufacturing date. 

Warranty obligations cease in case of non-observance of operating conditions established by 
the manufacturer and mechanical damage during operation. Warranty obligations do not cover 
the case of failure to present the device passport. 

1 pc 
1 pc 

1

4

. Completeness

Executive device Radio 8113 IP65
Passport
Individual packing

1 pc 

15.

Acceptance certificate

Executive  device  Radio  8113  IP65 (see  serial  number  on  the  first  page)  is  manufactured  in
conformance  with RB  TR 100376351.002-2003  and  essential requirements of technological
regulations, is approved by QCD and is classified as fit for operation.

16.

Potential problems

Problem 

Probable reason 

Fault elimination 

The  device  does  not 
operate 

a) t

here is no voltage;

b) t

he wires in terminals 1 and 2

 

are not clamped well. 

a) a

pply the voltage supply

 

at terminals 1 and 2.

b) c

lamp  the  wires  in  the

 

terminals 1 and 2. 

The  curtain  moves  in  an 
opposite direction when it 
is  controlled  by  the 
remote  control  button  of 
definite command. 

The  drive  wires  are  connected 
incorrectly. 

To  change  the  drive  wires 
connected  to  the  terminals 
4 and 5. 

The 

device 

operates, 

indicator  blinks  red  or 
green  but  the  voltage  is 
not supplied on drive. 

a) t

he jumper between terminals

 

6 and 7 is not installed;

b) t

he jumper between terminals

 

6 and 7 is not clamped well. 

a) i

nstall 

the 

jumper

 

between terminals 6 and 7;

b) c

lamp  the  jumper

 

between terminals 6 and 7. 

The device is not entered 
in the programming mode 

a)

 

l

atching  switch  is  connected,

 

and the button of one of

 

directions is pressed.

a)

 

c

hange  the  latching

 

switch on the switch

 

without fixation;

by 

pressing 

the 

programming button. 

b) switch cable

 

is out of service;

c) the switch is out of service

b) c

heck/change cable;

c) c

heck/change switch. 

The drive is turned on for 
a short time, roller shutter 
twitches and stops. 

a) t

he  short  command  mode  is

 

installed;

b) a

 short  command  time  is

 

installed, 

which 

is 

not

 

insufficient for the full closing of

 

roller shutter. 

a) i

nstall  the  necessary

 

mode;

b) i

nstall  the  necessary

 

command  time  or  reset  to

 

factory setting. 

The 

device 

is 

not 

controlled  using  remote 
control  and  key  switch, 
red visual indicator blinks 
permanently. 

a) i

ncorrect  operation  mode  of

 

safety inputs is installed;

b) t

here is an obstacle in area of

 

connected safety sensor;

c) c

able  leading  to  the  safety

 

sensor is impaired. 

a) i

nstall the mode of safety

 

inputs  in  accordance  with

 

the  sensor  or  reset  to

 

factory setting.

b)

remove  an  obstacle  in

 

area of sensor;

c)

check/change the cable. 

  

Made in the Republic of Belarus

 

Manufacturer: 

Nero Electronics LLC 
Belarus, 223016, FEZ Minsk, Minsk district, 
Novy Dvor rural council, 74 
tel./fax: (+375 17) 388-53-00, 

[email protected], 
www.neroelectronics.by

 

Representative office in Belarus:

 

Sketch LLC 
220073, Minsk, 2b Skryganova str, 
office 306 
tel./fax: (+375 17) 317-02-32

,

 

[email protected]

 

Representative offices in Russia:

 

SketchNerogroup LLC 
119361, Moscow, 15 Bolshaya Ochakovskaya Str., 
building 1
tel./ fax: (+7 495) 430-79-60, (+7 495) 735-64-47, 
(+7 495) 735-66-58, 

[email protected] 

Nero SPb LLC 
136070, St. Petersburg, 14 Komsomol Str., building

 

tel.: (+7 812) 987-51-56, (+7 981) 757-90-45, 

  

[email protected] 

Representative office in Ukraine:

 

Umnyye resheniya LLC 
03138, Kiev, Smolnaya Str.

, 9B

tel./fax: (+38 067) 679-51-22, (+38 044) 500-18-55, 

[email protected]

Содержание Radio 8113 IР65

Страница 1: ...and to the electric drive It is prohibited to use mounting wires and cables with polyethylene insulation or sheath It is prohibited to install the device at a distance less than 1 m from heating devices The holes in feedthrough plate should be punctured using a tool of smaller diameter than the input cable It is prohibited to supply 220 230 V voltage to the terminals 8 15 To consider 220 V as the ...

Страница 2: ...y of the device PM of remote controls Press and hold the programming button for more than 4 sec The visual indicator will flash red for a long time twice 5 Output the device from the PM of remote controls Press short the programming button The visual indication stops The device is automatically removed from the programming mode if no actions are performed with it during 32 sec 6 Operation modes Th...

Страница 3: ...epeatedly the device in the PM of operation mode if it is necessary 2 press and hold the programming button for more than 4 sec The visual indicator will flash yellow after 1 and 4 sec and then it will continue to blink double green light 6 Output the device from the programming mode Press twice shortly the programming button The visual indication stops The device is automatically removed from the...

Страница 4: ...d the device will execute the DOWN command the control from the remote controls and key switch will be blocked when the contact is opened the device will execute the UP command the control from the remote controls and key switch will be available after power re supplying when the contact is opened the device will execute the UP command after power re supplying when the contact is closed the device...

Страница 5: ...ec Retransmission of remote control marking is carried out only together with the control of power relay 8 1 Turning on off the retransmission function Action Indication 1 Input the device in programming mode of repeater from the standby mode Press and hold the programming button for more than 8 sec Visual indicator blinks green for certain times 2 Change the operation mode of repeater Turning on ...

Страница 6: ... or green but the voltage is not supplied on drive a the jumper between terminals 6 and 7 is not installed b the jumper between terminals 6 and 7 is not clamped well a install the jumper between terminals 6 and 7 b clamp the jumper between terminals 6 and 7 The device is not entered in the programming mode a latching switch is connected and the button of one of directions is pressed a change the l...

Отзывы: