Chapter 4 - Operation and Administration
WILINK I MODULAR BASE STATION SYSTEM MANUAL
172
Table 4-22: NPU Monitor Parameters Summary
Parameter
Range
Default
Run-Time
Updated
SU Phy Parameters
Bandwidth (MHz)
1 – 1.75
2 – 3.5
Note: PRO CPE supports only a 3.5
MHz Bandwidth
No
Uplink (Tx)
Frequency (MHz)
Depends on Frequency Bands Group
available for the AU, and the
Bandwidth.
No
SU Multirate and ATPC Parameters
Uplink Rate
Applicable only if Multirate in AU is
disabled:
1 – BPSK 1/2
2 – BPSK 3/4
3 – QPSK 1/2
4 – QPSK 3/4
5 – QAM16 1/2
6 – QAM16 3/4
7 – QAM64 2/3
8 – QAM64 3/4
New SU: Uplink Basic
Rate.
Connected SU: Last
used rate.
Yes
SU Ethernet Port Parameters
Ethernet Port
Configuration
1 – 10 Mbps Half Duplex
2 – 10 Mbps Full duplex
3 – 100 Mbps Half Duplex
4 – 100 Mbps Full Duplex
5 – Auto Negotiation
Auto Negotiation
No
SU Password
Password
Up to 20 printable characters, case
sensitive
installer Yes