6.
Open
the
meter
outlet
valve
slowly.
Open
a
down
stream
faucet
and
run
enough
water
to
dissipate
entrained
air
and
flush
the
line.
While
the
faucet
is
open,
verify
the
meter
is
operating
correctly.
7.
Turn
off
the
faucet
and
check
the
meter
installation
for
leaks.
See
Retrofit Meter Installation
Follow these steps to perform a retrofit meter installation.
1. Use a punch / screwdriver and hammer to punch out the tamper-proof seal pin on the
existing register head.
2. Remove the existing register by twisting counter-clockwise.
3. Twist the new E-CODER)R900
i
register head clockwise onto the meter body to install it.
4. Snap the new tamper-proof seal pin to secure the register to the meter body.
Connecting the E-CODER
®
)R900
i
™ Through-the-Lid Antenna
When ordering an external antenna for the E-CODER)R900
i
unit, Neptune recommends at
least a 6-foot cable to allow for easy removal of the pit lid when necessary.
Figure
4
–
E-CODER
®
)R900
i
™
Antenna
E-CODER
®
)R900
i™
Installation and Maintenance Guide
7
Chapter
3:
Installing
the
E-CODER
®
)R900
i
™