background image

D I R E C T   C O N N E C T   4   H E A V Y   D U T Y   -   V E R S I O N   1 . 0  
M A R C H ,   2 0 0 4  

Copyright 2004 - Neptune Systems 

All rights reserved 

 

1. Introduction 

The Direct Connect 4 Heavy Duty (DC4HD) allows the AquaController to directly switch up to 4 120V 
outlets. Each of the four outlets in the box can switch 12 Amps at 120 V AC. The total sum of all the current 
draw of the DC4 must be less than 15 Amps.  

2. Installation 

The DC4HD should be screwed onto a wall or cabinet in a dry location so that water damage is not 
possible. It is recommended that you follow these guidelines: 

1.

 

Mount the DC4HD above the water line of your tank. 

2.

 

Be sure to have drip loops on all cords plugging to the DC4HD. 

3.

 

Plug the DC4HD into a Ground Fault Interrupter Circuit (GFIC). 

 

Refer to the figure below for the positions of the connectors on the digital control box: 

Switch

X-10 In

X-10 Out

S1

S2

S3

S4

ON

OFF

 

Outputs (Output 1-4) 

The outlets are numbered as shown in the diagram on the top face of the DC4 below. Each outlet’s 
current is limited to 12 Amps and sum of the 4 outlet’s current may not exceed 15 Amps. 