background image

E

1

DT 

E1/PRI Splitter/Buffer

 

Copyright © 2005-2010 Somerdata Ltd. 

 

INSTALLATION AND OPERATION 

Applicable Products 

E1DT - E1/PRI Splitter / Buffer

 

Part Numbers: 

E1DT-ASSY-0058 

 

E1DT-ASSY-0059 

Document Reference 

E1DT-MAN-P112, Issue 4 

Publication Date 

31 October 2010 

Published by 

Somerdata Ltd. 
1 Riverside Business Park 
St Annes Road 
Bristol 
 
BS4 4ED 
UK 

Sales & Customer Support 

Phone: 

+44 (0)1179-634050 

Fax: 

+44 (0)1173 -302929 

E-Mail: 

[email protected] 

 

[email protected]

 

Website: 

www.somerdata.com

 

Содержание E1DT-ASSY-0058

Страница 1: ...t Numbers E1DT ASSY 0058 E1DT ASSY 0059 Document Reference E1DT MAN P112 Issue 4 Publication Date 31 October 2010 Published by Somerdata Ltd 1 Riverside Business Park St Annes Road Bristol BS4 4ED UK Sales Customer Support Phone 44 0 1179 634050 Fax 44 0 1173 302929 E Mail sales somerdata com support somerdata com Website www somerdata com ...

Страница 2: ...E1DT E1 PRI Splitter Buffer Installation and Operation REVISION HISTORY Issue Date Notes 4 Oct 2010 Contact details amended 3 21 Nov 2008 Updated 2 13 Feb 2008 Updated 1 2 Mar 2006 First Published ...

Страница 3: ...AL CONNECTIONS 4 1 INTRODUCTION 4 1 INPUT OUTPUT CONNECTOR PINOUTS 4 2 5 E1DT ASSY 0059 SIGNAL CONNECTIONS 5 1 INTRODUCTION 5 1 INPUT OUTPUT CONNECTOR PINOUTS 5 2 6 SPECIFICATIONS 6 1 LINE INTERFACE 6 3 SIGNAL 6 3 LINE CODE 6 3 DATA TYPE 6 3 SIGNAL AMPLITUDE 6 3 LINE CONNECTION 6 3 UN POWERED PERFORMANCE 6 3 BUFFER 6 4 MONITOR OUTPUTS STREAM A AND STREAM B 6 4 INPUT IMPEDANCE 6 4 MONITOR OUTPUT IM...

Страница 4: ... CROSSTALK 6 5 RESIDUAL OUTPUT 6 5 INPUT SIGNAL LOADING 6 5 POWER REQUIREMENTS 6 5 VOLTAGE 6 5 CURRENT 6 5 CONNECTOR 6 5 POWER ON INDICATION 6 5 AC ADAPTERS 6 5 ENVIRONMENTAL 6 6 TEMPERATURE 6 6 RELATIVE HUMIDITY 6 6 PHYSICAL 6 6 DIMENSIONS 6 6 WEIGHT 6 6 7 5BSUPPORT 7 1 47BWHAT TO DO IF YOU HAVE A PROBLEM 7 1 48BSERVICING MAINTENANCE AND REPAIRS 7 1 49BIF YOU NEED SUPPORT 7 2 50BSOMERDATA CONTACT...

Страница 5: ...DUCTION 8 1 56BWARRANTY TERMS AND CONDITIONS 8 2 9 8BNOTICES 9 1 55BGENERAL INFORMATION 9 1 DECLARATION OF CONFORMITY 9 2 SOMERDATA AND THE ENVIRONMENT 9 3 69BINTRODUCTION 9 3 70BCURRENT COMPLIANCE ACTIVITIES 9 3 71BRESTRICTION OF USE OF HAZARDOUS SUBSTANCES ROHS 9 4 10 INDEX 10 1 ...

Страница 6: ...E1DT E1 PRI Splitter Buffer Installation and Operation This page intentionally blank ...

Страница 7: ...ffer 16BUser Guides Printed copies can be supplied on request Please contact your local supplier or SomerData for ordering details Electronic copies Adobe Acrobat files are included on the SomerData CD ROM that is supplied with the original products Additional and updated copies of the CD ROM can be supplied on request Please contact your local supplier or SomerData for ordering details ...

Страница 8: ...E1DT E1 PRI Splitter Buffer Installation and Operation 1 2 This page intentionally blank ...

Страница 9: ... the Splitter Buffer Monitoring and recording equipment can be connected or disconnected without disturbing the line Line signals are split and fed into high impedance buffers that load the line signals by less than 0 1dB Low impedance outputs allow the monitoring equipment to be located up to 50m away from the line connection The design ensures that there is no interruption of the line signals wh...

Страница 10: ...for use with devices that monitor both Tx and RX on the same input connector This version is not compatible with SomerData PC VDR E1 PRI Recorders and R2D3 Data Capture Cards E1DT ASSY 0059 Provides the monitor outputs on two RJ 45 connectors pins 1 2 for use with devices that monitor Tx and RX on two input connectors This version is compatible with SomerData PC VDR E1 PRI Recorders and R2D3 Data ...

Страница 11: ... Recommended power source is a standard 6V 9V or 12V regulated 100mA power supply with 2 1 mm centre positive low voltage connector An unregulated power supply can be used provided that the input voltage to E1DT does not exceed 12V UK and European AC power adapters are available as options 6 Volts DC to 12 Volts DC 0 Volts ...

Страница 12: ...E1DT E1 PRI Splitter Buffer Installation and Operation 3 2 This page intentionally blank ...

Страница 13: ...RODUCTION 4 1 INPUT OUTPUT CONNECTOR PINOUTS 4 2 Introduction Both Tx and Rx monitor outputs are on a single RJ 45 connector Stream A E1DT ASSY 0058 should not be used with a SomerData PC VDR E1 PRI Recorder or R2D3 E1 PRI Data Capture Card see E1DT ASSY 0059 Connections should be made using standard CAT5 1 1 cable ...

Страница 14: ... It is the User s responsibility to ensure that this equipment is used in compliance with appropriate legislation relating to connection with telecommunications networks Monitor Outputs Pin Stream A 1 Output ve Tx direction 2 Output ve 3 Ground 4 Output ve RX direction 5 Output ve 6 Not used 7 Not used 8 Not used Line Input Output Pin Pin 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 ...

Страница 15: ...Introduction Tx and Rx monitor outputs are on two RJ 45 connectors Stream A for the Line Tx bitstream and Steam B for the Line Rx bitstream Both bitstreams appear on the Tx pins of the monitor output connectors for compatibility with with SomerData PC VDR E1 PRI Recorders and R2D3 E1 PRI Data Capture Cards Connections should be made using standard CAT5 1 1 cable ...

Страница 16: ...Connector Pinouts Monitor Outputs Pin Stream A Stream B 1 Output ve Output ve 2 Output ve Output ve 3 Ground Ground 4 Not used Not used 5 Not used Not used 6 Not used Not used 7 Not used Not used 8 Not used Not used Line Input Output Pin Pin 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 ...

Страница 17: ... AND STREAM B 6 4 E1DT ASSY 0058 6 4 E1DT ASSY 0059 6 4 INPUT IMPEDANCE 6 4 MONITOR OUTPUT IMPEDANCE 6 4 MONITOR OUTPUT LEVEL 6 4 MONITOR OUTPUT SIGNAL PRESENCE INDICATORS 6 4 MONITOR OUTPUT ISOLATION 6 4 INSERTION LOSS 6 4 OUTPUT TO INPUT GAIN VARIATION 6 4 OUTPUT BALANCE ERROR 6 4 NOISE NO SIGNAL LOADED INPUT 6 4 CROSSTALK STANDARD INPUT 6 4 MAXIMUM INPUT VOLTAGE 6 4 OUTPUT DRIVE CAPABILITY 6 5 ...

Страница 18: ...r Installation and Operation 6 2 POWER REQUIREMENTS 6 5 VOLTAGE 6 5 CURRENT 6 5 CONNECTOR 6 5 POWER ON INDICATION 6 5 AC ADAPTERS 6 5 ENVIRONMENTAL 6 6 TEMPERATURE 6 6 RELATIVE HUMIDITY 6 6 PHYSICAL 6 6 DIMENSIONS 6 6 WEIGHT 6 6 ...

Страница 19: ... limit 5V upper limit Line Connection Two RJ 45 connectors hard wired in parallel Optional BNC adapter cable available on request Line connection supports 120 balanced 75 unbalanced or monitor connection Note that there are no terminating devices in the line interface Un powered performance Applies to the pass though connection Crosstalk Better than 64dB Residual output Better than 35dB Input sign...

Страница 20: ... Monitor Output Impedance 120 balanced Monitor Output Level Unloaded 2 x Input Level Loaded Unity Gain Monitor Output Signal Presence Indicators LED indicator 1 2V p p signal detection threshold Monitor Output Isolation Transformer coupled 1500V RMS AC breakdown Insertion Loss Less than 0 2dB Output to Input Gain Variation Less than 0 1dB Output Balance Error 70db typical Noise no signal loaded in...

Страница 21: ...erformance Crosstalk Better than 64dB Residual output Better than 35dB Input signal loading Less than 0 1dB Power Requirements Voltage Operating 6 Volts DC to 12 Volts DC Absolute Maximum 0 25V lower limit 15V upper limit Current Less than 100mA Connector Low voltage 2 1mm centre positive Power on Indication LED indicator AC Adapters UK and European adapters are available as options ...

Страница 22: ...1DT E1 PRI Splitter Buffer Installation and Operation 6 6 Environmental Temperature 0 C to 70 C Relative Humidity 5 to 95 non condensing Physical Dimensions 55mm x 45mm x 25mm ABS enclosure Weight 50gms ...

Страница 23: ...hat to do if you have a problem Firstly please ensure that you have followed the installation connection and operation instructions in the appropriate User Guide Also check the Troubleshooting section where appropriate to eliminate common problems 48BServicing Maintenance and Repairs Please contact your supplier or SomerData for all questions relating to maintenance and repairs Any unauthorised at...

Страница 24: ... we will make our best efforts to provide prompt and friendly support by phone fax and e mail To diagnose a problem we will require you to provide a detailed description of the problem in the form of a Fault Report 50BSomerData Contact Information Address Somerdata Limited 1 Riverside Business Park St Annes Road Bristol BS4 4ED England Phone UK 01179 634050 International 44 1173 634050 Fax UK 0117...

Страница 25: ... or error messages Diagnostics information if available Sequence of events actions or other circumstances that triggered the problem How you are able to identify that there is a problem How you have been able to measure log or otherwise display the problem Details of the host PC if appropriate including operating system hardware configuration other hardware devices e g additional PCI cards other s...

Страница 26: ... packaging If the original packaging is not available it must be packed in such a way to avoid transit damage Damage sustained in transit is not covered under warranty Returned goods should be accompanied by documentation that indicates the RMA Number along with a detailed fault report and contact details name organisation phone fax and e mail Mark the RMA Number on the outside of the package Ship...

Страница 27: ...al and electronic equipment legislation provided that the product is free from radiation or biological contaminants and that no other legislation forbids the return 54BWaste Electrical Electronic Equipment WEEE In the UK Somerdata products may be recycled free of charge at any local authority recycling centre as long as the SomerData logo appears on the product and the following WEEE producer regi...

Страница 28: ...E1DT E1 PRI Splitter Buffer Installation and Operation 7 6 This page intentionally blank ...

Страница 29: ...ion This section describes SomerData s Warranty Terms and Conditions Where the SomerData product has been supplied via an authorised Reseller the Warranty and Support is between SomerData and its Reseller Local Warranty and Support arrangements should be agreed between the Reseller and the Customer The following information is subject to change without notice ...

Страница 30: ...t of service goods Any claim under this warranty shall expire unless made in writing immediately after the appearance of a claimed defect This warranty excludes damage from incorrect installation unauthorised modification negligence misuse or abuse or any item of equipment which has been serviced or worked on by anyone other than SomerData or its authorised representative SomerData will repair or ...

Страница 31: ...he information in this User Guide has been carefully checked and is believed to be accurate However SomerData assumes no responsibility for any inaccuracies that may be contained in this publication In no event will SomerData be liable for direct indirect special exemplary incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of...

Страница 32: ... description E1 Data Splitter Buffer Model E1DT ASSY 0058 E1DT ASSY 0059 Conforms to the following Product Specifications Safety IEC 950 EMC 89 336 EEC EN55022 Harmonised Standard The product complies with the requirements of the Electromagnetic Compatibility Directive 89 336 EEC as amended and the Low Voltage Directive 73 23 EEC and carries the CE marking accordingly Signed Position Technical Dir...

Страница 33: ...rtance of meeting our environmental obligations in the design manufacture and support of our products We have developed a broad appreciation of the impact of these directives on our entire business model from technical processes for materials to finished goods manufacturing 70BCurrent Compliance Activities The Company s current environmental compliance commitment has been structured to meet the fo...

Страница 34: ...ompliance requirements The maximum allowable hazardous substance at a homogeneous material level under the EU RoHS Directive is shown in the following table From 1st July 2006 all SomerData manufactured products use lead free soldering Substances Maximum Concentration Values ppm Lead and its compounds 1000 Mercury and its compounds 1000 Hexavalent Chromium Cr 6 1000 Cadmium and its compounds 100 P...

Страница 35: ... 2 Introduction 4 1 E1DT ASSY 0059 2 2 E1DT ASSY 0059 Signal Connections 5 1 Input Output Connector Pinouts 5 2 Introduction 5 1 End of life disposal 7 5 General Information 9 1 Index 10 1 Introduction 1 1 Notices Declaration of Conformity 9 2 General Information 9 1 SomerData and the Environment 9 3 Power Connection 3 1 Power Source 3 1 Product Description 2 1 4 1 Available Versions 2 2 E1DT ASSY...

Страница 36: ...ons 6 1 Buffer 6 4 Environmental 6 6 Line Interface 6 3 Physical 6 6 Power Requirements 6 5 Un powered Performance 6 5 Support End of life disposal 7 5 Returns 7 4 Support Requests 7 3 WEEE 7 5 SUPPORT 7 1 Support Requests 7 3 User Guides 1 1 Warranty 8 1 Introduction 8 1 Terms and Conditions 8 2 WEEE 7 5 ...

Отзывы: