manualshive.com logo in svg
background image

 

 

QL300 / QL500 

Quick Link ID-NET™ Connectors 

 
 

DESCRIPTION 

 

The QL series ID-NET™ connectors provide a fast and efficient way to 
cable an ID-NET™ network using standard cables. The QL300/500s are 
typically Master ID-NET™ connectors designed to be used with the 
QL100/150/200s ID-NET™ Slave connectors. 
 
The QL300 is a passive connection module which can be used in 
Standalone or ID-NET™ Master Multidata, Slave Multidata or Master 
Synchronized layouts. It provides separate ports for Power Supply, 
External Trigger, Digital I/O and Communication. Host communication is 
provided through connectivity to the reader Main serial interface 
(RS232/485) or Aux RS232 serial interface. 
ID-NET™ network and power supply signals are sent out to the next 
connected device by means of a dedicated port, however input power is 
not received from the network. Therefore each QL300 must be powered 
separately. 
 
The QL500 is an active connection module which can be used in 
Standalone or ID-NET™ Master Multidata, or Master Synchronized 
layouts. It provides separate ports for Power Supply, External Trigger, 
Digital I/O and Communication. Host communication is provided through 
the integrated Ethernet module which connects internally to the reader's 
Main serial interface. Reader Aux RS232 serial interface is also provided. 
ID-NET™ network and power supply signals are sent out to the next 
connected device by means of a dedicated port, however there is no 
network input connector and therefore it cannot be used as an ID-NET™ 
Slave. 
 
The QL series are compatible with the following readers: 
 

DS2100N DS4800 

Matrix 

400™ 

DS2400N  

Matrix 

200™ 

 
 

 

QL300 

 
 

 

QL500 

 
 
 
 

821001641 (Rev. A) 

CONNECTIONS 

 

ID-NET Out 

M12 5P Female (A-coded) 

Pin Function 

1 Shield 
2 Vdc 
3 GND 
4 ID+ 
5 ID- 

 

 

QL300 only

 (ID-NET In) 

M12 5P Male (A-coded) 

Pin Function 

1 Shield 
2 nc 
3 GND 
4 ID+ 
5 ID- 

 

 

QL500 only

 (Ethernet) 

RJ45 8P Female 

Pin Function 

1 TX+ 
2 TX- 
3 RX+ 
6 RX- 

4, 5, 7, 8 

nc 

P8 P1  

 
 

OVERALL DIMENSIONS 

 

129

 [4.56]

42

[1.49]

45

[1.59]

56

[1.98]

76

[2.67]

27

[0.

95]

 

QL300 

 
 
 

129

[4.56]

56

[1

.98]

42

[1.49]

45

[1.59]

27

[0.95]

76

 [

2

.67]

 

QL500 

 
 

Power 

M12 3P Male (B-coded) 

Pin Function 

1 Earth 
2 Vdc 
3 GND 

 

 

 

 

Trigger 

M12 4P Female (A-coded) 

Pin Function 

1 +V 
2 nc 
3 -V 
4 I1+ 

 

 
 

MOUNTING 

 
There are two self-threading screws provided for mounting the QLs to 
various wooden or plastic surfaces. Mounting to other surfaces such as 
concrete walls or metallic panels requires user-supplied parts (screws, 
screw anchors, nuts, etc). Keep in mind that the connected reader must 
have its Chassis grounded to Earth, see paragraph "Grounding". 
 
QLs can also be mounted to a Bosch Frame using the BA200 mounting 
accessory. 
 
The distance between mounting bushings is given in the overall 
dimension diagram for each QL. 
 

 

NOTE 

IP65 protection is provided when the cables (or QLs) 
are properly mated.

 

 
 

GROUNDING 

 
There are two general rules to follow regarding network grounding: 
 

1)  The network Shield must only be connected to Earth ground at 

one point (the Master). 

 

When using isolated power supplies, Earth grounding can be 
accomplished through the CAB-PW-EXT accessory cable and the 
BA400 or QL300/500 Power connector. 
 

 

Power Supply 

Earth ground connection 

QL300 

Power 

CAB-PW-EXT

 

 
 

2)  All reader Chassis must be connected to Earth ground. 

 

All the readers in the network must have their 

Chassis connected to 

Earth ground

 either by: mounting to conductive metal brackets or 

frames which are connected to Earth ground; or through the CBX or 
SC4000; or through the QL bushing. 
 
In the case of grounding through the CBX or SC4000, connect the 
Earth signal to a good earth ground and set the internal Chassis 
jumper to 

Earth

 
In the case of grounding through the QL bushing, connect a flying 
lead from the mounting bushing to an Earth ground. The mounting 
bushing is internally connected to the reader Chassis. 

*

 pins 4 and 5 are nc for QL500. 

 
 

*

 pins 4, 5, 12 and 15 are nc for QL500. 

 
 

 

CAUTION 

Do not connect GND and SGND to different (external) 
ground references. GND and SGND are internally 
connected through filtering circuitry which can be 
permanently damaged if subjected to voltage drops over 
0.8 Vdc.

 

 
 

ACCESSORIES 

 

Description Part 

Number 

Connection 

Cables  

 

CAB-PW-EXT M12 POWER 
EXTENSION CABLE 

93A051381 Power 

CBL-1480-01 THIN M12/5P 
MALE/FEMALE 1M 
CBL-1480-02 THIN M12/5P 
MALE/FEMALE 2M 

970101021 

 

970101022 

ID-NET Out/In

CAB-AUX04 15P DSUB TO DB9 
SERIAL CABLE 3M 

93A051386 I/O 

Port 

Terminators  

 

CBL-1490 TERM. RESIST. 
THIN M12/5P/MALE 

970101069 ID-NET 

Out 

CBL-1496 TERM. RESIST. 
THIN M12/5P/FEMALE 

970101082 ID-NET 

In 

Field Mountable Connectors 

 

 

FMC400 M12 3P F. CONN. POWER 

93ACC1884 

Power 

Mounting  

 

BA200 Bosch Adaptors 

93ACC1822 

 

 
The FMC accessory connectors can be used to make custom External 
Power and Service cables in case the standard cables don't satisfy the 
application requirements. 

Reader 

25P D-Sub Female 

 

1

14

25

13

Pin Function 

Pin  Function 

1, 

shell, 

both bushings 

Reader Chassis

 

 

2 TXM 

14 nc 

3 RXM 

15 nc 

RTSM 

*

 

16 nc 

CTSM 

*

 

17 nc 

6 I2A 

18 I1A 

7 GND 

19 GND 

8 O1+ 

20 RXA 

9 nc 

21 TXA 

10 I2B 

22  O1- 

11 O2+ 

23  ID+ 

12 O2- 

24  ID- 

13 Vdc 

25  GND 

I/O Port 

15P HD D-Sub Female 

 

1

6

15

5

11

10

 

Pin Function 

Pin  Function 

1 O1+ 

9  I2A 

2 TXA 

10 O2- 

3 RXA 

11 I2B 

RXM 

*

 

12 

TXM 

*

 

CTSM 

*

 

13 GND 

6 O1- 

14 SGND 

7 Vdc 

15 RTSM 

*

 

8 O2+ 

   

mm 

in 

mm 

in 

Отзывы: