COR User Guide
Page 15
ADDITIONAL NOTES:
o
Whenever the LED panel is lit red, a specific error message will also be shown on
APEX Fusion and APEX Local dashboards; these are not shown on the Classic
Dashboard. The error conditions must be enabled however, for these status
messages to appear.
o
The LED panel may continue to be red for up to one minute after an error
condition has cleared or has been resolved.
o
Similarly, the display of an error message on the APEX Fusion or APEX Local
dashboard may persist for 1-2 minutes after an error condition has cleared or was
resolved.
COR DRIVER BUTTONS
The function of the two buttons on the COR driver will vary depending on the operating
mode of the COR driver.
During normal APEX-connected operations, the left button may be used to turn the COR
output OFF and then back to AUTO. The right button may be used to activate or cancel
Feed Cycle A.
❖
To turn the COR output OFF, press and hold the left button for 3 seconds; the
status LED panel will turn pink to indicate that the output is OFF. The OFF state
will also be shown on the COR tile on the APEX Local, APEX Fusion, or Classic
Dashboard.
❖
To return the COR output to AUTO, press and hold the left button for 3 seconds;
the status LED panel will turn orange to indicate that the output is back in the
normal AUTO state. The AUTO state will also be shown on the COR tile on the
APEX Local, APEX Fusion, or Classic Dashboard.
❖
To activate FEEDA, press and hold the right button for 3 seconds; the status LED
will turn green to indicate that FEEDA is active. The status LED panel will return
to normal orange illumination when the FEEDA timer expires or is canceled using
an APEX Dashboard Feed tile.
❖
To cancel FEEDA from the COR driver, press and hold the right button again for 3
seconds. The COR right button may be used to cancel FEEDA even if FEEDA was
activated by means other than the COR button.
The COR’s right button can activate FEEDA only; it is not configurable for activation of
Feed Cycles B, C, or D instead.