NEP BDM-250-208A Скачать руководство пользователя страница 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. INTRODUCTION   

1.1 Pre

x   

Dear customer, thank you for choosing the BDM-250 micro inverter from NEP. 

We  hope  you  will 

nd  our  products  meet  your  need  for  renewable  energy. 

Mean

me, we appreciate your feedback regarding our products.   

1.2 Grid-

ed PV System   

Grid-

ed PV system consists of PV panels, grid-

ed inverter and junc

on boxes. 

The DC output from the PV panels is converted into AC energy and feedback to 

the  grid  through  the  BDM-250.  BDM-250  series  PV  micro  inverter  contains 

isola

on transformer with basic insula

on between PV input and AC grid output. 

The PV panel terminals on BDM-250 shall not be earthed via external wiring, for 

BDM-250 connects PV panel to earth via an internal earth fault interrup

ng 1A 

fuse.   

1.3 H

o

w t

o

 Use This Manual   

This manual provides detailed product informa

on and installa

on instruc

ons 

for the BDM-250 micro solar inverter. Please read through this manual before 

installa

on and opera

on. 

 

WARNING:

 This indicates a situa

on where failure to follow instruc

ons 

may be a safety hazard or cause equipment malfunc

on. Use extreme 

cau

on and follow instruc

ons carefully.   

1.4 Label 

The  label  is  located  on  the  side  of  the  inverter.  The  informa

on  on  the  label 

includes technical data as well as type, 

rmware version and serial number of the 

device. Safety instruc

ons on the label are listed and explained below: 

 

Danger!     

The term “danger” describes an issue which, if ignored can cause 

personal injury.

 

 

A

en

on!     

With  the  term  “a

en

on”  a  circumstance  is  listed  which  may 

cause property damage if disregarded.

 

 

Instruc

ons for use! 

Under “Instruc

ons for Use“, it is pointed out that installa

on and 

opera

ng  instruc

ons  are  to  be  read  and  understood  before 

installa

on or repair. 

 

Cau

on, hot surface!     

Under “Cau

on, hot surface”, it should be noted that surfaces of 

equipment may be hot and create a burn hazard. 

 

Special disposal instruc

ons! 

With “Note Separate Disposal”, it is pointed out that this product 

may  not  be  disposed  of  with  normal  garbage.  An  improperly 

conducted disposal can lead to damage to the environment.

 

 

CE mark 

The  product  complies  with  essen

al  requirements  of  relevant 

direc

ves of EU 

2. SAFETY INSTRUCTION 

WARNING:     

PLEASE READ THIS MANUAL BEFORE INSTALLATION. ANY DAMAGE TO THE PRODUCT DUE TO NOT 

FOLLOWING THIS MANUAL IS NOT COVERED BY THE WARRANTEE.   
ALL THE INSTALLATION SHOULD BE DONE BY CERTIFIED ELECTRICIAN.   
BESIDES THE CABLE CONNECTORS, NOTHING INSIDE THE INVERTER SHOULD BE MODIFIED.   
ALL INSTALLATION SHOULD FOLLOW THE LOCAL ELECTRIC CODES. FURTHER PROTECTION ON THE 

AC WIRING FROM THE INVERTERS SHOULD BE PROVIDED AND MAY BE REQUIRED BY LOCAL AND 

NATIONAL  WIRING  REGULATIONS.  THIS  PROTECTION  IS  LIKELY  TO  INCLUDE  RESIDUAL  CURRENT 

DEVICES,  EARTH  FAULT  MONITORS  AND  CIRCUIT  BREAKERS.  THIS  PRODUCT  MAY  CAUSE  AC 

CURRENT  WITH  A  DC  COMPONENT.    IF  A  RESIDUAL  CURRENT-OPERATED  PROTECTIVE  DEVICE 

(RCD)  OR  A  MONITORING  DEVICE  (RCM)  IS  USED  FOR  PROTECTION  IN  CASE  OF  DIRECT  OR 

INDIRECT  CONTACT,  ONLY  AN  RCD  OR  RCM  OF  TYPE  B  IS  ALLOWED  ON  THE  AC  SIDE  OF  THIS 

PRODUCT. 
NEVER DISCONNECT PV MODULE FROM THE MICRO-INVERTER WITHOUT FIRST ISOLATING THE AC 

MAINS.    ALL  PV  CONNECTORS  AND  AC  CONNECTORS  ARE  FORBIDDEN  TO  BE  DISCONNECTED 

UNDER LOAD BEFORE SWITCHING OFF THE CIRCUIT BREAKER ON THE AC BRANCH. 
PLEASE CONTACT AUTHORIZED SERVICE AGENTS FOR ANY SERVICE WORK. 
BDM-250 IS  A GRID-TIED  SOLAR INVERTER.    IT  MAY REQUIRE  APPROVAL  FROM  LOCAL  UTILITY 

COMPANY TO CONNECT IT TO THE POWER GRID. 
BDM-250 DOES NOT INCLUDE COMPONENTS THAT CAN BE SERVED BY CUSTOMERS.   

WARNING:     

WHEN    THE    PHOTOVOLTAIC    ARRAY  IS    EXPOSED  TO    LIGHT,  IT    SUPPLIES    A    DC 

VOLTAGE TO THE MICRO-INVERTER. 

3. FCC COMPLIANCE 

This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 

provide  reasonable  protec

on  against  harmful  interference  in  a  residen

al 

installa

on.  This  equipment  generates  uses  and  can  radiate  radio  frequency 

energy  and,  if  not  installed  and  used  in  accordance with  the  instruc

ons,  may 

cause  harmful  interference  to  radio  communica

ons.  However,  there  is  no 

guarantee  that  interference  will  not  occur  in  a  par

cular  installa

on.  If  this 

equipment  does  cause  harmful  interference  to  radio  or  television  recep

on, 

which  can  be  determined  by  turning  the  equipment  o

  and  on,  the  user  is 

encouraged  to  try  to  correct  the  interference by  one  or  more  of  the  following 

measures:     

 Reorient or relocate the receiving antenna.   

 Increase the separa

on between the equipment and the receiver.   

 Connect the equipment into an outlet on a circuit di

erent from that to   

  which the receiver is connected.   

 Consult the dealer or an experienced radio/TV technician for help.   

Changes  or  modi

ca

ons  not  expressly  approved  by  the  party  responsible  for 

compliance may void the user’s authority to operate the equipment.   

 

 

 

03

02 

03

Содержание BDM-250-208A

Страница 1: ... 9 Meander Grove Cameron Park NSW2285 China Address No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 SAA 122309 N136 BDM 250 240A BDM 250 AU BDM 250 LV BDM 250 208A BDM 250 EU Installa on and Opera on Manual ...

Страница 2: ...ocedure Step 1 Install the AC Branch Circuit Junc on Box Step 2 A ach the BDM 250 to the Racking Step 3 Connect the BDM 250 Wiring Harnesses Step 4 Ground the System Step 5 Complete the connec on map and connect the PV Modules 5 COMMISSIONING 6 OPERATING INSTRUCTIONS 7 TROUBLRSHOOTING MAINTENANCE 8 SPECIFICATION 9 WARRANTY AND PRODUCTION INFORMATION WARRANTY CARD 01 02 02 02 02 02 03 03 04 04 04 0...

Страница 3: ...ommunity and powered by electricity from solar wind and micro turbines Outside China the company has opera on offices in Chicago U S and Vancouver Canada The technology founders of the company are well known experts in the fields of power electronics automa c control signal processing and communica ons Each of the founders has mul ple U S and world patents in their specialty areas They received Ph D ...

Страница 4: ...STALLATION SHOULD BE DONE BY CERTIFIED ELECTRICIAN BESIDES THE CABLE CONNECTORS NOTHING INSIDE THE INVERTER SHOULD BE MODIFIED ALL INSTALLATION SHOULD FOLLOW THE LOCAL ELECTRIC CODES FURTHER PROTECTION ON THE AC WIRING FROM THE INVERTERS SHOULD BE PROVIDED AND MAY BE REQUIRED BY LOCAL AND NATIONAL WIRING REGULATIONS THIS PROTECTION IS LIKELY TO INCLUDE RESIDUAL CURRENT DEVICES EARTH FAULT MONITORS...

Страница 5: ...rranty does not cover acts of God such as lightning strikes and since lightning strikes can occur anywhere it is best prac ce to install surge protec on as part of any solar installa on Installa on of surge protec on devices should follow vendor instruc ons Installa on Procedure WARNING DO NOT CONNECT BDM 250 TO THE UTILITY GRID OR ENERGIZE THE AC CIRCUIT S UNTIL YOU HAVE COMPLETED ALL OF THE INST...

Страница 6: ...roximately six inches long and are terminated with single pole connectors The AC connectors are oppositely sexed so that mul ple inverters can be connected to form one con nuous AC branch circuit 1 Orient the first BDM 250 in each branch with its male connector facing the junc on box The junc on box AC interconnect cable has a female connector The BDM 250 can be mounted with either side facing up t...

Страница 7: ...area Refer to local regula on for minimum size requirement for ground conductor size Step 5 Complete the connec on map and connect the PV Modules BDM 250 connec on Map is a diagramma c representa on of the physical loca on of each BDM 250 in your PV installa on The virtual array in NEP micro inverter gateway BDG 256 is created from the map you create Complete the connec on map Each BDM 250 has a r...

Страница 8: ...e BDM 250 is powered on when sufficient DC voltage from the module is applied The status LED will start flashing a er sufficient DC power is applied as an indica on that the BDM 250 is live Status standby The LED light is on by 2 second and off by 2 seconds Status producing power The LED light is on by 1 second and off by 1 second Status producing power and communica ng with BDG 256 The LED light is on ...

Страница 9: ...YOUR DISTRIBUTOR FOR MAINTENANCE Disconnec ng a BDM 250 from the PV Module To ensure the BDM 250 is not disconnected from the PV modules under load adhere to the following disconnec on steps in the order shown 1 Disconnect the AC by opening the branch circuit breaker 2 Disconnect the first AC connector in the branch circuit 3 Cover the module with an opaque cover 4 Using a DC current probe verify t...

Страница 10: ...ent to the Array Adc 0 OUTPUT AC Rated AC Output Power W 220 Nominal Power Grid Voltage Vac 230 Current maximum con nuous Aac 1 0 Current inrush Peak and Dura on 12A 15us Nominal Frequency Hz 50 Power Factor cos phi fixed 0 99 Maximum Output Fault Current Aac 2 2A peak Maximum Output Overcurrent Protec on Aac 6 3 Maximum Number of Units Per Branch 15 SYSTEM EFFICIENCY Peak Efficiency 96 30 CEC Efficien...

Страница 11: ...xport Processing Zone Tsingtao China 266113 Phone 86 532 87963900 Fax 86 532 81100917 What does this warranty not cover Claims are limited to repair and replacement or if in NEP s discre on that is not possible reimbursement up to the purchase price paid for the product NEP will be liable to you only for direct damages suffered by you and only up to a maximum amount equal to the purchase price of t...

Страница 12: ...ODUCT AND IS WHERE PERMITTED BY LAW IN LIEU OF ALL OTHER WARRANTIES CONDITIONS GUARANTEES REPRESENTATIONS OBLIGATIONS AND LIABILITIES EXPRESS OR IMPLIED STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT HOWEVER ARISING WHETHER BY CONTRACT TORT NEGLIGENCE PRINCIPLES OF MANUFACTURER S LIABILITY OPERATION OF LAW CONDUCT STATEMENT OR OTHERWISE INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY OR ...

Страница 13: ...d 1781 Riverview Ave Tracy CA 95377 Australia Address 9 Meander Grove Cameron Park NSW2285 China Add No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 ...

Отзывы: