background image

AccuPoint

®

 Advanced  

Next Generation User Guide

Содержание AccuPoint Advanced Next Generation

Страница 1: ...AccuPoint Advanced Next Generation User Guide...

Страница 2: ...of the Instrument 06 Cleaning the Instrument Chapter 4 Preparing the Instrument for Use 07 Power 08 Home Page 09 Running Quick Tests 09 Results Screen 09 Add Notes 09 Retest 10 Sample Procedure Chapt...

Страница 3: ...ager Software 20 Sampler Type Surface Liquid or Alkaline Phosphatase 20 Setting the Pass Marginal and Fail Thresholds 21 Troubleshooting Chapter 11 Technical Information 25 Electromagnetic Compatibili...

Страница 4: ...t of providing greater sensitivity through a clearer distinction between very low levels of ATP The AccuPoint Advanced NG instrument offers enhanced navigation touch screen wireless data transfer capa...

Страница 5: ...a food debris yeast and mold Bioluminescence is a chemical reaction that produces light ATP bioluminescence occurs when ATP from a sample comes into contact with luciferase an enzyme found in fireflie...

Страница 6: ...NEOGEN com 4 Eject button Full color touch screen display USB data and charging port RFID antenna Sampler compartment On Off and navigation d pad Operating Principles and Technology...

Страница 7: ...esting liquids Be sure to remove and properly dispose of samplers after each reading from the instrument The sampler reagents and their cartridges are non toxic and may be disposed of without any spec...

Страница 8: ...at may be contaminated To clean the lens use the AccuPoint Advanced NG cleaning swab moistened with a solution of isopropyl alcohol 70 Be sure to turn the instrument upside down while cleaning the len...

Страница 9: ...too low a notification will appear recommending you charge the instrument immediately Once the battery level reaches a critically low state a notification will appear warning that the instrument is p...

Страница 10: ...e AccuPoint Advanced NG instrument connects to the data manager software on your PC Battery Icon indicates the amount of battery life left on the instrument Menu Navigation menu with sites results set...

Страница 11: ...the last used site and will not initiate a quick test Selecting quick test will always use the quick test site A progress indicator will appear displaying the progress of the sample Once complete the...

Страница 12: ...ampling Under standard testing select the correct site to be tested 03 Sample your site by drawing a 4 x 4 in 10cm x 10cm square With a vertical and horizontal back and forth motion fill in the square...

Страница 13: ...e sampler and begin test Note keep instrument upright while the sample is being read 08 The RLU value will display along with a symbol for pass marginal or fail 09 On the results screen users have the...

Страница 14: ...ny tests taken in that session To log in select the username field Navigate to the appropriate username in the list by scrolling with the up and down buttons on the d pad or use the search field on th...

Страница 15: ...thout the use of a plan subset proceed to area selection To run a standard test as a part of a plan subset select select plan Navigate to the appropriate plan in the plans list by scrolling with the u...

Страница 16: ...ure can be used to avoid confusion and save time by automatically pulling up the appropriate group based on the location of a physical RFID tag See the RFID section for more information RFID tags are...

Страница 17: ...tton to confirm the added note Notes will be stored in the comments field when results are imported into the data manager software Retest To run a retest of the same site remove sample and select the...

Страница 18: ...ll dim when the instrument is idle Off Timeout Adjusts the amount of time before the instrument automatically powers off when the instrument is idle Auto Select Site Automatically selects the next sit...

Страница 19: ...data transfer to occur A Wi Fi icon with a lock will appear when the instrument is connected to Wi Fi and ready to transfer To sync results select sync results to transfer test results wirelessly to...

Страница 20: ...rate when it recognizes the RFID tag A green check mark will appear next to groups which have RFID tags assigned Be sure to note on the RFID sign which group has been associated with it This will help...

Страница 21: ...munication the sync results button can be used to send new readings data to the active data manager database When the sync results button is pressed the device will attempt to re establish a secure co...

Страница 22: ...two sampling modes surface and liquid Both the AccuPoint surface and access samplers are designed to be read in surface mode The AccuPoint liquid sampler is read in liquid mode A water droplet symbol...

Страница 23: ...NEOGEN com 21 Troubleshooting Error 01 Door open during unit initialization while powering on Error 02 Try to run test when unit is being charged Additional Features...

Страница 24: ...NEOGEN com 22 Error 03 Reminder to remove used sampler after testing is complete Error 04 Please wait baseline in progress Additional Features...

Страница 25: ...NEOGEN com 23 Error 05 Leaving the door open when the unit is trying to take a baseline reading Error 06 The unit battery is low charge unit soon by connecting to the USB charger Additional Features...

Страница 26: ...07 The unit battery is depleted the unit is shutting down Connect the unit to the USB charger Error 08 Tilt warning flag unit was not kept upright during the test Test results are marked with this fla...

Страница 27: ...andard s Operationissubjecttothefollowingtwoconditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation...

Страница 28: ...this product There is no warranty of merchantability of this product or the fitness of the product for any purpose NEOGEN shall not be liable for any damages including special or consequential damage...

Страница 29: ...NEOGEN Corporation 2021 NEOGEN and AccuPoint are registered trademarks of NEOGEN corporation Lansing MI 48912 U S NEOGEN com...