8
2.1.2.2. Panelized Board
The sequence is same to single PCB, but please pay some attention to several points below.
The row and column is determined by the positioning of PCB on working area. The horizontal direction is
the column. Enter data in the row and column.
About the data collection of “left bottom” , “left top” and “right top”, we should take the
“left bottom” as the basic, and then go to set “left top” and “right top”. Once all the data is collected, the
machine can calculate and process the information of panelized PCB.
Please refer to the data collecting method of each position information as following:
The data of “left bottom” is collected according to first component in programming file. Press “align” find
the left bottom panel which is nearest to the feeding entrance, after saving the data, it will return to the “PCB
information” automatically.
The data of “left top” is collected according to component ( the component is same to that on “left bottom”).
Press “align” find the left top panel which is furthest to the feeding entrance, after saving the data, it will
return to the “PCB information” automatically.
The data of “right top” is collected according to component (the component is same to that on “left bottom”).
Press “align” find the right top panel which is furthest to the feeding entrance, after saving the data, it will
return to the “PCB information” automatically.
After setup, click “create panelized list”, the data will be generated accordingly in the blank. You can also
double-confirm each position by clicking” Align”. ( Note, the three positions must be the same component from
different panelized board)