10. DMX CHART
2CH Mode
CH1
CH2
Puff Volume ( P.xxx)
Fan ( F.xxx)
5-255 5%-100%
16-255 6%-100%
0-4 off
0-15
5%
11. TROUBLESHOOTING
12. POWER CONNECTED BUT NO SMOKE IS EMITTED
This troubleshooting guide is meant to help solve
simple problems. If a problem occurs, carry out the
steps below in sequence until a solution is found.
Once the unit operates properly, do not carry out
following steps. If the problem persists, refer servic
-
ing to a qualified technician.
1.
Check the power supply. Plug the unit into
grounded electric power supply socket with
proper voltage.
2.
Disconnect fog machine from electric power
supply. Replace fuse with one of the same type.
3. Keep sufficient fluid in tank.
4. Check if pump is working (with fluid flow or
not).
5. Check if the heater is heating (touch the panel
to see if it is warming).
6. Check your controller if in correct connection.
7. Check your DMX address setting.
Содержание STEAM F700