P. 8
Neo ION 132 F -
English version
Replacement of the fuse
Trouble Shooting
Need to replace with same type and rating, which
originally installed in the device.
Step One:
Unplug power cable from main power.
Step Two:
Unscrew the fuse holder out of the hous-
ing with a screwdriver.
Step Three:
Remove the broken fuse and replace
with an exact same type of new fuse.
Step Four:
Insert the fuse holder back to the hous-
ing and screw tight and reconnect power.
Problems
Possible reasons
Checking or solutions
Device not
power up
Powercon or power cable damaged
Change a good power cable to try
Faulty power supply
Replace new power supply
Pan/Tilt error
or vibrate
Faulty Pan/Tilt PCB
Replace PT001 PCB
Faulty opto sensor
Replace opto sensor OP001
Cable loosen
Check the cable connect to OP001
Lamp off
Temperature protection
Check the temperature from menu
Fan not working
Check the fan speed info from menu
Faulty Lamp
Replace new Lamp
Dimmer and strobe set at 0
Set dimmer and strobe channel at 255
Faulty power supply
Replace new power supply
Device not response
to DMX
Faulty communication IC
Replace the IC with back-up one in the
display PCB
Faulty display PCB
Replace new display PCB
Wrong DMX addressing
Check the address and setting
Faulty DMX cable
Change to a good DMX cable
Содержание ION 132 F
Страница 5: ...P 5 Neo ION 132 F English version Static gobo wheel...
Страница 15: ...P 15 Neo ION 132 F 7 DIMENSIONS DRAWING English version...
Страница 19: ...P 19 Neo ION 132 F Rueda de gobo est tica Versi n Espa ol...
Страница 29: ...P 29 Neo ION 132 F 7 DIMENSIONES Versi n Espa ol...
Страница 30: ...P 30 Neo ION 132 F...