3.3.1 Left Knob:
selector with heat setting
the
device
is
turned
off
the fan runs at low power
the fan is running at full power
the heating element works at half power
the heating element is working at full power)
3.3.2 Right Knob:
Thermostat
dial
3.3.3
P
ower light:
Above
is the power
indicator
light
3.3.4
W
ork indicating lamp:
Below is the work
indicator
light
4. Introduction:
4.1
Depending
on the power
cord
type this fan heater may be
used
only in
household
, warehouses
and
workshops,It
incorporates a
Adjustable
trip
thermostat
and
a self-resetting thermal cut-out to control the heating
elements.
The thermostat feels the air temperature
and
controls the
surrounding
temperature.The
fan motor is not
controlled
by thermostat
and
it keeps on working when the thermostat cuts off the heating
element.The
self-resetting
thermal cut-out will switch off the heater to ensure the safety when
overheating.
4.2
When using the heater for the first time, you may notice a slight emission of
smoke.
This is quite normal
and
it stops after a short
time.
The
heating element is
made
of stainless steel
and
was
coated
with protection oil by
production.
The smoke is
caused
by the left oil when
heated.
5. Using Instructions:
5.
1The machine is
equipped
with a
Adjustable
trip thermostat, which automatically shuts
down
when the machine is not in an upright position (falling
back
and
forth).When
it is
moved
to an upright position, the
device
will return to normal
operation.Always
keep the machine upright before starting
5.
2Position the fan heater so that it
stands
upright on a firm surface
and
at a safe
distance
from wet
environments
and
flammable
objects.
5.
3 Connect the fan heater to the
mains.
5.
4 Set the
Adjustable
trip thermostat knob to the
MAX
and
let the heater operate with full
power.
5.
5 The fan heater will switch on when the heating selector is set to one of the power
settings.
5.
6 Once the room reaches the
required
temperature, heating element will stop working but fan also working
.Once
the temperature
decreased,
the
heating element will be
working.
The fan heater now starts
and
stops automatically
and
thus keeps the room temperature
constant.
5.
7 Before switch off the heater, please turn the thermostat to
MIN
position
and
turn the switch to fan position, let the appliance cool
down
for two
minutes then turn off the heater
and
pull out the
plug.
6. Trouble shooting:
You can
solve
many common problems easily,
saving
you the cost of a possible
service
call.
Try the suggestions below to see if you can
solve
the
problem before calling the
service
centre.
Problem
Possible cause
Treatment
The heater
does
not operate,
even
when it is
plugged
in
and
the switch
thermostat are
switched
on
.
The plug is loose,
bad
connection
Pull out the plug, check the connection of the plug
and
socket.
Then connect
again.
No
power in socket outlet
Insert
the plug in a proper socket
The heating element glowing
The input
voltage
is too high or too low
Use power supply
according
to the rating on the label
The air inlet grill is
blocked
Keep
the heater far way from articles like curtain,
plastic bag, paper
and
other things which can
cover
the inlet or can be easily
cover
on the air inlet
The appliance
didn’t
heat up, or
only
ventilator
worked
The switch was not put at heating setting
Turn the switch to heat setting
The thermostat
operated
Turn the thermostat
and
listen if there is open/close
voice.
If
there is no click
and
the thermostat is not
damaged,
the heater will automatic switch on when
the appliance
cooled
down
The self-resetting cut-out
operated
Turn the heater off
and
inspect the blockage of inlet or
outlet.
Disconnect the plug and wait at least 10
minutes
for the protection system to reset before
attempting to restart the
heater.
Abnormal noise
The appliance is not
stands
upright
Put the heater on a
level
surface
7.Cleaning and Maintenance
: