I
NSTALLATION
3
LOCAT ION AND ORIENTATION
For safe operation, install th
e Neo One Mini
in a location where: -
•
It is at least 0.3 meters (12 inches) away from illuminated surfaces
and combustible materials.
•
It is not easily touched or bumped.
•
It is protected from rain and moisture.
•
There is at least 0.1 meters (4 inches) clearance around the fans
and air vents.
•
There are no flammable materials nearby. The
Neo One Mini
may
be installed in any orientation as described below or
placed
directly on a stage or floor. The intense light can burn or melt parts
within a distance of 0.3 meters (12 inches).
When installing fixtures side-by-side, avoid illuminating one fixture
with another.
Clamp
The Neo One Mini includes a bracket for attaching a rigging clamp with
12 mm (1/2 in.) hardware.
TO R IG THE FIXTURE WITH A CLAMP
WARNING! Ensure a safety Cable is secured to the safety anchor
point at the base of the fixture.
1.
Verify that the clamp is undamaged and can bear at least
10 times the weight of the fixture. Verify that the structure
can bear at least 10 times the weight of all installed fixtures,
clamps, cables, auxiliary equipment, etc.
2. Bolt a clamp to the included bracket with a grade 8.8
(minimum) M12 bolt and locknut, or as recommended by
the clamp manufacturer, through the 13 mm hole in the
bracket.
3.
Align the bracket with the keyholes in the base. Insert both
locking pins into the holes and turn both levers a full 1/4 turn
clockwise to lock.
The fasteners are locked only when turned