MODE 1
(“122 style”)
Both switches are latching types; press
once to change speed, press again to go back to the previous
setting. Selecting FAST speed overrides any setting on the
STOP switch.
MODE 2
(“760 style”)
Both switches are latching types. The
STOP mode overrides any setting on the SLOW / FAST
switch. You can however “preset” a speed with the SLOW /
FAST switch which becomes active when leaving Stop mode
by pressing STOP again.
MODE3
Both switches are latching types; STOP overrides any
setting of the SLOW / FAST switch. If SLOW / FAST is pressed
from STOP, SLOW will always be selected.
MODE 4
Both switches are momentary (unlatched) types
(press
and hold). Pressing the STOP button causes the
Ventilator to STOP until the switch is released. Pressing the
FAST / SLOW button causes the Ventilator to run at FAST
speed until the switch is released. The default mode (when
neither switch is pressed) is SLOW.
MODE 5
This setting is similar to MODE 1, except that the
SLOW / FAST switch acts in a momentary
(unlatched) manner
(press and hold). STOP is a latching switch (press and
release). FAST mode overrides any setting on the STOP
switch.
MODE 6
This setting is similar to MODE 2, except that the
STOP switch acts in a momentary
(unlatched) manner (press
and hold). SLOW / FAST is a latching switch (press and
release). STOP mode overrides any setting on the SLOW /
FAST switch.