Association Groups:
Group
Number
Maximum
Nodes
Description
1
4
Lifeline
2
4
Send control commands to associated devices such as relay
module, lighting, etc.
3
4
Send Notification to associated devices in this group.
4
4
Sending Sensor Binary Report to associated devices in this
group.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain
configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT:
Controllers may only allow configuring signed values. In order to set values
in the range 128 ... 255 the value sent in the application shall be the desired value minus 256.
For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 =
minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.
Parameter 1: Sensitivity Level Setting
This parameter defines the sensitivity of PIR sensor. At the first time of test, it is
recommended to test the sensor with movements from a farthest end of the coverage area .
If movements cannot be detected sensitively, simply adjust the sensitivity level by changing
this parameter.
Size: 1 Byte, Default Value: 12
Setting Description
8 - 255
Sensitivity Level Setting.
Parameter 2: On/Off Duration
This parameter can determine how long the associated devices should stay ON status. For
instance, this parameter is set to 30(second), PIR sensor will send a BASIC SET Command to
an associated device with value basic set level if PIR sensor is triggered, and the associated
devices will be turned on, and stay in this status for 30(second) before it is turned off
automatically.
Size: 2 Byte, Default Value: 30
Setting
Description
5 - 600
On/Off Duration Setting