NEO Coolcam Motion Sensor 2 Скачать руководство пользователя страница 3

Reset to factory default  

This device also allows to be reset without any involvement of a Z-Wave controller. This 
procedure should only be used when the primary controller is inoperable.  

1. Remove the cover of PIR sensor. 
2. Make sure the sensor is powered. 
3. Press and hold the reset button for 10-15 seconds, then LED lights would flash red color 1 
time first, then 5 times on and off alternately. 
4. Release the code button. 

Safety Warning for Batteries 

The product contains batteries. Please remove the batteries when the device is not used. Do 
not mix batteries of different charging level or different brands.  

Installation 

Holder Installation

 

Fix the holder with screws and screw stopper or put the sticker on the bottom of motion 
sensor then fix it on the wall. 
 

 

 

Battery Installation

 

 

1.Make sure PIR placed within the Z-Wave network range of gateway. 
2.PIR is recommended to be fixed at the height of 2- 4 meters off the ground. 
3.When install PIR, please keep it far away from places where air temperature changes 
sensitively, e.g., around air conditioners, refrigerators, stoves and so on.  
4.Furniture, large bonsai or other spacers shouldn’t be placed within PIR’s detection area. 
5.When installing PIR, please keep it away from stairs, elevators and other obstructions. Make 
sure these obstructions are outside of PIR’s detection area. 
6.After instaling PIR, please test whether PIR works properly or not, if there is false alarm 
from PIR, please install PIR in another place. 

Содержание Motion Sensor 2

Страница 1: ...ng it powered on please do not operate it within 20s 2 Make sure PIR sensor is located within the Z Wave network range of gateway 3 Set Z Wave gateway into inclusion mode Refer to gateway user manual...

Страница 2: ...detect infrared radiation from outside Under room temperature all items have radiation Human beings are warm blooded animals with stable infrared radiation so are most easily to be detected That s why...

Страница 3: ...allation Fix the holder with screws and screw stopper or put the sticker on the bottom of motion sensor then fix it on the wall Battery Installation 1 Make sure PIR placed within the Z Wave network ra...

Страница 4: ...false alarms reported check if there are any moving objects within sensor s detection area such as trees blowing in the wind cars passing by windmills False motion alarms may be caused by masses of m...

Страница 5: ...ayed in the gateway Red icon means the battery needs replacing and then mobile app would receive a message power level is low please remember to replace battery from gateway In order to avoid false al...

Страница 6: ...action You can press the button once to wake up the sensor and send wakeup notification to gateway If press successfully LED light will blink one time Quick trouble shooting Here are a few hints for...

Страница 7: ...value the same logic applies Values greater than 32768 may needed to be given as negative values too Parameter 1 Sensitivity Level Setting This parameter defines the sensitivity of PIR sensor At the...

Страница 8: ...PIR Detector Parameter 5 Ambient illumination Lux Level This parameter can be set a lux level value which determines when light sensor is activated If the ambient illumination level falls below this v...

Страница 9: ...meter 5 PIR sensor will not send a BASIC_SET command frame Size 1 Byte Default Value 0 Setting Description 0 Disable 1 Enable Parameter 9 Ambient illumination Lux Level Report This parameter defines h...

Страница 10: ...ed event will be sent to controller when device detects a movement event 1 he motion detected event will be sent to controller only once until device report motion cleared event Parameter 99 Ambient l...

Страница 11: ...ype 1 CR123A Device Type Multilevel Sensor Firmware Version 03 50 Z Wave Version 04 26 Z Wave Product Id 0x0258 0x0003 0x108d Supported Command Classes Basic Sensor Binary Sensor Multilevel Associatio...

Страница 12: ...the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of remov...

Отзывы: