Standard Operating Procedure - LEDs  

 

The status of the energizer and the fence 

is displayed on the front panel of the 

energizer, as follows: 

Under 

normal operating conditions:

 

Conditions that if ignored 

will sound the alarm:

 

Mains present, battery charging 
Fence energized 
No fence alarm 
No gate alarm 
No service condition 

If all are flashing, fence is 
operating correctly 

Restore mains – see Note 1 
Turn energizer on – see Note 2 
Alarm condition 
Alarm condition 
Possible installer intervention required – see Note 3 

Fence good 
Concern – see Note 4 
Service fence – see note 4 
Service fence 
Alarm/Fence faulty 

Содержание WIZORD

Страница 1: ...WIZORD Electric Fence Energizer User Manual ...

Страница 2: ...uarantee 4 Nemtek group outlets 5 Standard Operating Procedures 6 Standard Operating Procedures Notes 7 Standard Operating Procedures LEDs 8 Features Functions 9 IEC Safety Information 10 Document revision history 10 Table of Contents 2 ...

Страница 3: ... general information is available on our web site at http www nemtek com COMPANY PROFILE The NEMTEK Group of Companies manufacture and distribute intelligent electronic security and perimeter control systems and have been involved in the security industry since 1990 We have our own research and development team designing and manufacturing a full range of globally competitive electric fence energiz...

Страница 4: ...urned to one of the Nemtek Group outlets The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse LIMITATION OF GUARANTEE The guarantee does NOT apply to defects resulting from acts of God modifications made by the buyer or any third party misuse neglect abuse accident and mishandling EXCLUSIVE REMEDIES The remedies provided herein are...

Страница 5: ...h Africa CAPE TOWN Tel 27 0 21 386 3742 27B Concord Crescent Airport City Fax 27 0 21 386 5573 Cape Town South Africa NELSPRUIT Tel 27 0 13 752 2187 Waterval Ave Riverside Industrial Fax 27 0 13 752 2188 Nelspruit South Africa KWAZULU NATAL Tel 27 0 31 701 2125 19 Henwood Road Fax 27 0 31 701 2125 Pinetown South Africa AUSTRALIA Tel 08 9303 9855 Unit 5 19 Innovation Circuit Email nemtek bigpond ne...

Страница 6: ...en the unit is switched to the Low Voltage Mode ALARM INDICATION The fence and gate inputs are configured to trigger external alarms and the internal buzzer The service condition will activate the buzzer only Be aware that should there be a prolonged power failure the battery may run low and cause the service light to flash If the mains interruption is sufficiently long the unit will shut down and...

Страница 7: ... parts within the energizer Please refer all problems to qualified service personnel 4 It is possible that under mains failure conditions the energizer will operate at reduced energy levels and the fence status display will not be fully lit The mains should be restored first before checking the physical fence condition 5 Keep the fence clear of vegetation and do a periodical check for any slack fe...

Страница 8: ...red will sound the alarm Mains present battery charging Fence energized No fence alarm No gate alarm No service condition If all are flashing fence is operating correctly Restore mains see Note 1 Turn energizer on see Note 2 Alarm condition Alarm condition Possible installer intervention required see Note 3 Fence good Concern see Note 4 Service fence see note 4 Service fence Alarm Fence faulty ...

Страница 9: ...ne minute Wizord 2 only or immediate entry alarm HIGH LOW VOLTAGE The energizer Wizord 2 only can be switched between low high voltage mode EARTH LOOP MONITORING For additional security the facility to use earth loop monitoring is provided for EXTENDED OPERATION DURING MAINS FAILURE The unit detects the mains failure and reduces the fence output energy AUXILIARY 12VDC OUTPUT A 12 Volts DC fused ou...

Страница 10: ...d for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Electric fencing can be lethal Avoid head contact with the fence Ask the installer to explain the options of current limiting resistors Rev 1 5...

Отзывы: