background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TURNING YOUR UNIT ON / OFF: 

In the default state, the energizer can be turned on or off by holding the plastic tab 
over the corresponding logo on the fascia of the unit. The unit will beep once when 
turned on and twice when turned off. 

 

FENCE STATUS INDICATION: 

 

The unit will indicate that a condition is currently active (fence fault, gate open, or 
service  condition)  if  the  corresponding  LED  is  flashing;  e.g.  if  the  fence  LED  is 
flashing, the fence voltage is currently not satisfactory. If the fence alarm indication 
LED is lit continuously, there was a fence alarm condition previously but the fence 
voltage  is  now  satisfactory.  Similarly,  if  the  gate  alarm  indication  LED  is  lit 
permanently,  the  gate  opening  time  exceeded  the  entry  delay  period  but  is  now 
closed. If the gate indication LED is flashing, the gate is still open. 
 
If the mains supply is present the power LED is lit and it will go out with a mains 
failure. The On LED will be lit when the unit is switched on and it will be off when it 
is switched off. The On LED will flash when the unit is switched to the Low Voltage 
Mode. 

 

ALARM INDICATION: 

 

The fence and gate inputs are configured to trigger external alarms and the internal 
buzzer.  The  service  condition  will  activate  the  buzzer  only.  Be  aware  that,  should 
there be a prolonged power failure, the battery may run low and cause the service 
light  to  flash.  If  the  mains  interruption  is  sufficiently  long,  the  unit  will  shut  down 
and there will be no indication of mains failure. 

 

RESETTING THE ALARM: 

 

Switch the unit off with the Nemtek tab or remote key-switch. This will silence the 
siren (if it has not already timed-out), internal buzzer and will switch the strobe off. 
One  of  the  alarm  lights  will  be  flashing  or  will  remain  lit  to  indicate  the  source  of 
the  alarm.  A  permanently  lit  indicator  notifies  the  user  that  the  fault  no  longer 
exists.  In  the  latter  case  simply  turning  the  energizer  On  again  will  clear  the 
memory condition. A flashing alarm light illustrates that the fault condition persists. 
In  this  case  rectify  the  condition  which  caused  the  alarm.  To  reset  and  clear  the 
memory  condition  turn  the  energizer  On  and  Off  and  On  again.  Only  if  the  alarm 
condition is resolved will the energizer operate without alarm activation. 
 

Standard Operating Procedure 

Содержание WIZORD

Страница 1: ...WIZORD Electric Fence Energizer User Manual ...

Страница 2: ...uarantee 4 Nemtek group outlets 5 Standard Operating Procedures 6 Standard Operating Procedures Notes 7 Standard Operating Procedures LEDs 8 Features Functions 9 IEC Safety Information 10 Document revision history 10 Table of Contents 2 ...

Страница 3: ... general information is available on our web site at http www nemtek com COMPANY PROFILE The NEMTEK Group of Companies manufacture and distribute intelligent electronic security and perimeter control systems and have been involved in the security industry since 1990 We have our own research and development team designing and manufacturing a full range of globally competitive electric fence energiz...

Страница 4: ...urned to one of the Nemtek Group outlets The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse LIMITATION OF GUARANTEE The guarantee does NOT apply to defects resulting from acts of God modifications made by the buyer or any third party misuse neglect abuse accident and mishandling EXCLUSIVE REMEDIES The remedies provided herein are...

Страница 5: ...h Africa CAPE TOWN Tel 27 0 21 386 3742 27B Concord Crescent Airport City Fax 27 0 21 386 5573 Cape Town South Africa NELSPRUIT Tel 27 0 13 752 2187 Waterval Ave Riverside Industrial Fax 27 0 13 752 2188 Nelspruit South Africa KWAZULU NATAL Tel 27 0 31 701 2125 19 Henwood Road Fax 27 0 31 701 2125 Pinetown South Africa AUSTRALIA Tel 08 9303 9855 Unit 5 19 Innovation Circuit Email nemtek bigpond ne...

Страница 6: ...en the unit is switched to the Low Voltage Mode ALARM INDICATION The fence and gate inputs are configured to trigger external alarms and the internal buzzer The service condition will activate the buzzer only Be aware that should there be a prolonged power failure the battery may run low and cause the service light to flash If the mains interruption is sufficiently long the unit will shut down and...

Страница 7: ... parts within the energizer Please refer all problems to qualified service personnel 4 It is possible that under mains failure conditions the energizer will operate at reduced energy levels and the fence status display will not be fully lit The mains should be restored first before checking the physical fence condition 5 Keep the fence clear of vegetation and do a periodical check for any slack fe...

Страница 8: ...red will sound the alarm Mains present battery charging Fence energized No fence alarm No gate alarm No service condition If all are flashing fence is operating correctly Restore mains see Note 1 Turn energizer on see Note 2 Alarm condition Alarm condition Possible installer intervention required see Note 3 Fence good Concern see Note 4 Service fence see note 4 Service fence Alarm Fence faulty ...

Страница 9: ...ne minute Wizord 2 only or immediate entry alarm HIGH LOW VOLTAGE The energizer Wizord 2 only can be switched between low high voltage mode EARTH LOOP MONITORING For additional security the facility to use earth loop monitoring is provided for EXTENDED OPERATION DURING MAINS FAILURE The unit detects the mains failure and reduces the fence output energy AUXILIARY 12VDC OUTPUT A 12 Volts DC fused ou...

Страница 10: ...d for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Electric fencing can be lethal Avoid head contact with the fence Ask the installer to explain the options of current limiting resistors Rev 1 5...

Отзывы: