background image

 

Taut Wire 

Node 

 

Installer Manual

 

Содержание Taut Wire Node

Страница 1: ...Taut Wire Node Installer Manual ...

Страница 2: ...ay Outputs 10 4 6 Jumper Configuration 11 5 Software Setup 12 5 1 Startup 12 5 2 User Menus 12 5 2 1 Default Menu 12 5 2 2 Tautwire Channel 1 State 12 5 2 3 Tautwire Channel 2 State 12 5 2 4 History Channel 1 12 5 2 5 History Channel 2 12 5 2 6 Event Log 13 5 2 7 System Restart 13 5 3 Installer Menus 13 5 3 1 Channel 1 Installer Menu 13 5 3 2 Channel 2 Installer Menu 16 5 3 3 Log Repeat Interval 1...

Страница 3: ...ushbuttons and jumpers The Node 1 board offers a basic relay interface whereas the Node 2 board is equipped with an Ethernet port for network connectivity It is recommended that the Node board is installed inside the NEMTEK Power Supply Module which can be powered from a standard 230V 50Hz household socket and includes battery backup in the event of power failure 2 DISCLAIMER NEMTEK Holdings Pty L...

Страница 4: ... Africa CAPE TOWN Tel 27 0 21 386 3742 27B Concord Crescent Airport City Fax 27 0 21 386 5573 Cape Town South Africa NELSPRUIT Tel 27 0 13 752 2187 Waterval Ave Riverside Industrial Fax 27 0 13 752 2188 Nelspruit South Africa KWAZULU NATAL Tel 27 0 31 701 2125 19 Henwood Road Fax 27 0 31 701 2125 Pinetown South Africa AUSTRALIA Tel 08 9303 9855 Unit 5 19 Innovation Circuit Email nemtek bigpond net...

Страница 5: ...f Separate Sensor Channels 2 Number of Relay Outputs 2 One per channel Number of Digital Outputs 4 Number of Digital Inputs 4 Network Communication RJ45 10 100Mbps Ethernet Digital inputs and outputs can only be configured with network commands Outputs are open collector potential free Limited with resettable fuse Inputs have internal pull up resistors to 5V Relay outputs can be configured to be t...

Страница 6: ...ed A suitable mains transformer with an output of 16 Vac may be installed to match the mains socket output voltage The transformer should have a power rating of at least 30 VA Directly powering the Node board using the on board connector see 4 4 with an approved power supply that conforms to the specifications listed in 4 1 To mount the Node board inside the NEMTEK Power Supply module follow the s...

Страница 7: ... 5 terminals Take care to use the 12 V supply output and make sure of the polarity as indicated on the PCB On the power supply unit without a mains transformer connect the mains transformer to the 16 Vac input terminal 6 of the power supply by using the supplied pigtail wire with connectors Reconnect the battery and fit the cover of the power supply before reconnecting the mains supply 3 Power Sup...

Страница 8: ...y Channel 1 Relay Output Channel 2 Relay Output 12V Output Digital Outputs Ground Digital Inputs OLED Display Relay Configuration Jumpers Taut Wire Sensor Channel 1 Taut Wire Sensor Channel 2 RJ45 Network Connection Configuration Push Buttons ...

Страница 9: ...4 5 Connection Examples A 9 4 5 1 Taut Wire Sensors 4 5 2 Digital Outputs ...

Страница 10: ...4 5 Connection Examples B 10 4 5 3 Digital Inputs 4 5 4 Relay Outputs ...

Страница 11: ... to be either a potential free dry contact or a wet contact that supplies 12V by configuring the relevant jumpers as shown in the figure below The configuration is also indicated on the board below the jumpers 4 6 Jumper Configuration 11 ...

Страница 12: ...ll Taut Wire sensors addresses that are currently in alarm will be displayed next to Alm All Taut Wire sensors adresses that are not connected on experiencing communication errors will be displayed next to Com Details of the alarms or errors can be seen in History menu 5 2 3 Tautwire Channel 2 state The same information mentioned in 3 2 2 is given for channel 2 5 2 4 History Channel 1 The alarm an...

Страница 13: ...aller menus can be accessed by holding down any of the pushbutton during system power up or restart Like the user menus scrolling through the different menus is done with the left and right pushbuttons To automatically address a new installation execute the following steps in order by referring to the relevant menus below Decommission channel 1 2 section 5 3 1 1 Count sensors on channel 1 2 sectio...

Страница 14: ...ep sequence 5 3 1 3 Address sensors Channel 1 Before commencing sensor addressing ensure no sensors are in alarm Press the centre pushbutton to start the addressing sequence The default starting address is 1 This value can be changed manually with the left and right pushbuttons if a different sensor address needs to be programmed Note that sensor addresses must be filled sequentially and it is not...

Страница 15: ...red Note that if the selected sensor count is more than the actual sensors connected to the board the additional sensors will generate a communication error For example if 12 sensors are selected but only 10 sensors are connected the additional 2 sensors will generate a communication error 5 3 1 5 Set Channel 1 comms fail The threshold sets the amount of times the board will try to establish commu...

Страница 16: ...e to the minute value Press the centre pushbutton to select the value Note that the change needs to be saved before it will take effect see 3 3 4 5 3 4 Set TW Node address Set the network address from 1 to 63 for the Node This is the address of the Node that will be displayed on the FG7 network controller and Fenceprobe software and should not be confused with the IP address For more information r...

Страница 17: ... Sensor Alarms 1 Sensor Right Check intrusion 2 Sensor Left Check intrusion 3 Sensor Left and Right Check intrusion 4 Service Right Sensor at stress limit to right Reset tension on sensor 5 Sensor and Service Right Check intrusion reset tension on sensor 6 Sensor Left and Service Right Check intrusion reset tension on sensor 7 Sensor Left and Right and Service Right Check intrusion reset tension o...

Страница 18: ...suitable enclosure away from excessive heat and damp Never exceed the maximum ratings given in section 4 as this may lead to permanent damage to the board Do not install the Taut Wire sensor communication wires near electric fence or other high voltage or current carrying conductors Rev D 20 March 2019 Print Code ...