MERLIN STEALTH: Introduction
INTRODUCTION
The Merlin Stealth Range of Energizers is functionally very similar to the previous generation of
Merlin energizers.
It is recommended that a suitable training course is attended before altering the functionality of
the energizer. Ensure that municipal by-laws are adhered to.
The Merlin Stealth Range includes earth-loop monitoring and has an RS232 port for diagnostics
and connectivity. The embedded software incorporated in the unit may be revised from time to
time. For the latest features or revisions please visit our web site at:
www.nemtek.com
To load factory default settings: Unplug the energizer from the mains and disconnect one of the
battery terminals. Reconnect the battery terminal and apply mains to the energizer. Within 65
seconds of reconnecting the battery terminal, the key sequence 2 3 8 9 # must be entered on
the keypad. In each of the appropriate tables the shaded row indicates the factory default
setting.
The Merlin Stealth Energizer™ may be networked. This can be done for either multiple energizer
synchronization or for controlling and monitoring a large number of energizers. An advanced
installers course is compulsory for installers wanting to access these features.
Electric fencing can be lethal. Please inform the user to avoid head contact with the
fence. Explain to the user the options of current limiting resistors and the low-voltage
operation of the energizer.
DANGER:
DO NOT PRESS THE SWITCH (WITH THE SPRING ATTACHED) WITH THE LID OPEN!
DO NOT MODIFY OR ALTER THE UNIT
Содержание MERLIN STEALTH MASTER