20
MERLIN STEALTH
Installer Notes
INSTALLATION NOTES:
1.
Keep the wires to the fence separate from the keypad/gate/siren/strobe/
mains/remote wiring.
2.
Do
not try and modify the unit.
Any unauthorised modifications will null and void
the warranty and possibly render the unit illegal.
3.
If the
remote On/Off
facility is used, the wire between the remote switch and the
energizer can be up to a 100m. For security reasons it is better to use an intelligent
FOB on the keypad bus.
4.
A
remote receiver
can obtain
12VDC
from the keypad bus. Current consumption
must not exceed 1 Amps. This
is not sufficient to supply power
for an armed
response transmitter.
5.
The
siren
and
strobe light
together must not draw more than 1.75Amps.
6.
To connect a
radio alarm transmitter
or
alarm panel
to the energizer use an
isolation relay between the strobe light output and the panel. Never use the
energizer battery to power a radio alarm transmitter or alarm panel.
7.
The wire between the
magnetic gate switch
and the energizer can be up to a
100m but must not run in parallel with the fence wires. The gate switch must be
open circuit if the gate is open.
8.
The
remote keypad cable
must not exceed a 100m in total.
Avoid running this
cable in parallel with any fence (high voltage) wires.
9.
You can connect a total of four keypads or FOB units to one energizer. Each must
have a unique address setting.
10.
Use
high voltage insulation wire
between the fence and energizer, including the
earth wire. Never run these wires in the same conduit or through the same hole as
the low voltage wiring.
11.
Always use ferrules or line clamps to connect two
high voltage wires
together.
Avoid using different types of material for connections like copper on steel.
12.
The
fence
must be
earthed
properly with at least one earth electrode as close as
possible to the energizer. The distance between the fence earth electrode and other
earth systems shall be not less than 10 m.
13.
When
replacing
the
lid
of the energizer hook the top in first while holding it an
angle and then push it closed at the bottom. Fasten the lid down with the two cap
screws.
14.
Always
test
the
fence
alarm for a short and open-circuit after installation at the
furthest point on the fence.