15
Energizer Operation
When the energizer is connected to a suitable DC supply (11-15Vdc) the LCD
backlight colour will indicate the state of the energizer.
Blue:
The energizer is switched off
Green:
The energizer is switched on and operating within acceptable limits
Amber:
The energizer is switched on but operating outside acceptable limits
Red:
The energizer could be on or off depending on service/alarm conditions
Blue:
The energizer i
s off and the display
will show the energizer model in large
characters.
-
The DC supply voltage to the energizer
is displayed in the top right corner
Green:
The energizer is on and the LCD
displays shows the following:
-
In large characters the output fence
voltage in kilovolts (kV) measured
between the Earth and HV terminal
-
In large characters the output current
measured in Ampere (A) going into
into the fence
-
In small characters the stored energy
inside the energizer measured in
Joules (J)
-
In small characters the percentage (%)
effort that the energizer is working at to
achieve the indicated fence voltage
-
If the input supply voltage drops
below the set level the green
display will go yellow/green
-
If the input supply voltage drops
below the very low voltage setting
the green display will go yellow