Caution: To minimize the risk of accidental activation,
always ensure the tool is switched off before
performing any maintenance work on the rotary
hammer, as well as during transportation and storage.
2.
To attach front auxiliary safety handle, twist the bottom of the
handle to the left to loosen the metal ring
3.
Slide the metal ring over the chuck. Tighten the bottom of the
handle to the right, to secure the front safety handle in place.
Pressurizing the Rotary Hammer for Underwater Use
Your rotary hammer can be used in any wet conditions, and can be
submerged and used underwater at depths of up to 164ft ( 50m ).
Before submerging the rotary hammer to any depth, it must be
pressurized.
1.
Remove the red cap from the pressure valve on the base of the
rotary hammer.
2.
Attach a pump, such as the hand pump supplied with the
rotary hammer, to the valve.
9