APPLICATION

XR luminaires are designed for use indoors, outdoors, wet locations, areas containing moisture, dirt, 

corrosion, vibration and rough usage.  The XR luminaire has been certified for use on marine vessels inside, 

outside, and in other severely wet saltwater environments. 

Certified to:   

UL 844, UL 1598, UL 1598A, and UL 8750;

 

 

 

CSA C22.2 No. 250.0 and CSA C22.2 No. 250.13

   

Housing:  

 

Copper-free Cast Aluminium with Polycarbonate lens

Input Voltage:   

Based on luminaire suffix in table below: Suffix - AC: 120-277 VAC | Suffix - HV: 347-480 VAC  

Electrical Ratings: 

Connections:   

3 x 3/4” NPT Conduit | Black: Line | White: Neutral | Green: Ground

   

Optional:   Violet: 0-10V Dimming (+)  |  Grey: 0-10V Dimming (-)

  

 

 

For connections use wire rated to a minimum of 90°C.  Class 1 Wiring only.

 

 

 

All supply field wiring must be rated 300V minimum for luminaires with suffix AC, 

 

 

 

600V minimum for luminaires with suffix HV.

Ambient

Temperature Range:       

XR8: -50°C to +75°C

                                                XR10: -50°C to +74°C

                                                XR15: -50°C to +74°C

                                                XR20: -50°C to +67°C

Ingress Protection: 

IP66  | Suitable For Wet Locations. Marine Outside Type (Salt Water)

SURFACE/CEILING 

MOUNTING INSTALLATION

TM

Nemalux

I N D U S T R I A L

XR-GEN

rev. A-13

E477827

1-14

www.nemalux.com  |   [email protected]  |   Tel 403•242•7475  |   Fax 403•243•6190 

MADE IN CANADA

E477827

*PENDING*

*PENDING*

LUMINANCE

XR8 

XR10 

XR15 

XR20 

RATED VOLTAGE

[Volts]

RATED WATTAGE

[Watts]

INPUT

VOLTAGE

AC

HV

AC

HV

AC

HV

AC

HV

120-277
347-480
120-277
347-480
120-277
347-480
120-277
347-480

Flood: 47 Optic: 60
Flood: 49 Optic: 64
Flood: 55 Optic: 75
Flood: 58 Optic: 77

Flood: 84 Optic: 103
Flood: 91 Optic: 107

Flood: 141 Optic: 156
Flood: 148 Optic: 160

FREQUENCY

[Hz]

50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60

Содержание XR-GEN Series

Страница 1: ...Class 1 Wiring only All supply field wiring must be rated 300V minimum for luminaires with suffix AC 600V minimum for luminaires with suffix HV Ambient Temperature Range XR8 50 C to 75 C XR10 50 C to...

Страница 2: ...via retention strap Note Screws are captive fasteners and will remain attached to the cover for ease of reinstall and to prevent loss of fasteners 5 0in 126mm 5 2in 132mm 16 0in 405mm 17 3in 441mm 0...

Страница 3: ...0 A for control needs 0 10V Controller must sink current from LED driver 0 10V control connections NOTE To aid in assembly and provide protection against ingress use of a petrolatum or soap thickened...

Страница 4: ...REEN VIOLET GREY TM Nemalux I N D U S T R I A L XR GEN rev A 13 4 14 www nemalux com sales nemalux com Tel 403 242 7475 Fax 403 243 6190 MADE IN CANADA Any additional wiring not shown has been capped...

Страница 5: ...ead lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure STEP 5 Insert and tension M6 set screw to pole to lock rotation STEP 6 Resume inst...

Страница 6: ...ly gasket to mount with adhesive backed side Torque to 5 Nm 45 in lbs STEP 5 Install Back Cover Plate with 4x M4 Flat head screws and adhesive backed gasket Apply gasket with adhesive side applied to...

Страница 7: ...assembly Torque fasteners to 5 Nm 45 in lbs STEP 5 Thread installed wiring through opening in XR high vibration yoke mount and install XR luminaire into yoke The raised circular bosses on the XR cheek...

Страница 8: ...curved slot the luminaire may be configured for an upward or downward adjustable swing STEP 4 Thread installed wiring through openings in yoke mount cheek plate and yoke mount bracket Mount yoke asse...

Страница 9: ...ly and provide protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrit...

Страница 10: ...n through the outer band of the unit and fastening a closed loop Secondary safety hardware must be rated for a minimum of 110lbs Install remaining loop of secondary safety chain or steel cable to suit...

Страница 11: ...dy near AC input Secure the surge protector and driver lead wires together as close to the origin of the driver lead wires as possible using the provided zip tie STEP 4 Wire according to wiring instru...

Страница 12: ...t conductor and White leads from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case PS 1 GRO...

Страница 13: ...provided zip tie STEP 4 Wire according to wiring instructions on Page 12 14 Refer to NEC CEC codes and follow all applicable local standards STEP 5 Close XR Wiring Cover Ensure the retention cable is...

Страница 14: ...t conductor and White leads from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case PS 1 GRO...

Отзывы: